BACKGROUND: The recently developed real-time 3-dimensional echocardiography (RT3DE) is a promising imaging method to quantify cardiac chamber volumes and their functions in clinical practice. However, normal reference values of RT3DE parameters have not been fully investigated in a large, healthy Japanese population. METHODS AND RESULTS: This study consisted of 410 healthy subjects aged from 20 to 69 years who had a RT3DE at one of the 23 collaborating institutions. All subjects had no history of cardiac disease and no risk factors. The mean values in men and women were as follows: 50 ± 12 ml/m(2) and 46 ± 9 ml/m(2) for left ventricular (LV) end-diastolic volume index, 19 ± 5 ml/m(2) and 17 ± 4 ml/m(2) for end-systolic volume index, 61 ± 4% and 63 ± 4% for ejection fraction, 64 ± 1 2 g/m(2) and 56 ± 11 g/m(2) for mass index, 23 ± 6 ml/m(2) and 24 ± 6 ml/m(2) for left atrial (LA) maximum volume index, 10 ± 3 ml/m(2) and 10 ± 3 ml/m(2) for minimum volume index, and 58 ± 6% and 58 ± 6% for percent volume change. LV sizes decreased with age, whereas LV mass index did not change. LA sizes slightly increased with age. CONCLUSIONS: This multicenter investigation determined normal reference values for LV and LA sizes, and their functional parameters on RT3DE in a large, healthy Japanese population. The results of the present study support the use of RT3DE for the diagnosis and management of cardiovascular disease.
BACKGROUND: The recently developed real-time 3-dimensional echocardiography (RT3DE) is a promising imaging method to quantify cardiac chamber volumes and their functions in clinical practice. However, normal reference values of RT3DE parameters have not been fully investigated in a large, healthy Japanese population. METHODS AND RESULTS: This study consisted of 410 healthy subjects aged from 20 to 69 years who had a RT3DE at one of the 23 collaborating institutions. All subjects had no history of cardiac disease and no risk factors. The mean values in men and women were as follows: 50 ± 12 ml/m(2) and 46 ± 9 ml/m(2) for left ventricular (LV) end-diastolic volume index, 19 ± 5 ml/m(2) and 17 ± 4 ml/m(2) for end-systolic volume index, 61 ± 4% and 63 ± 4% for ejection fraction, 64 ± 1 2 g/m(2) and 56 ± 11 g/m(2) for mass index, 23 ± 6 ml/m(2) and 24 ± 6 ml/m(2) for left atrial (LA) maximum volume index, 10 ± 3 ml/m(2) and 10 ± 3 ml/m(2) for minimum volume index, and 58 ± 6% and 58 ± 6% for percent volume change. LV sizes decreased with age, whereas LV mass index did not change. LA sizes slightly increased with age. CONCLUSIONS: This multicenter investigation determined normal reference values for LV and LA sizes, and their functional parameters on RT3DE in a large, healthy Japanese population. The results of the present study support the use of RT3DE for the diagnosis and management of cardiovascular disease.
Authors: John Eng; Robyn L McClelland; Antoinette S Gomes; W Gregory Hundley; Susan Cheng; Colin O Wu; J Jeffrey Carr; Steven Shea; David A Bluemke; Joao A C Lima Journal: Radiology Date: 2015-10-20 Impact factor: 11.105
Authors: Hena N Patel; Tatsuya Miyoshi; Karima Addetia; Michael P Henry; Rodolfo Citro; Masao Daimon; Pedro Gutierrez Fajardo; Ravi R Kasliwal; James N Kirkpatrick; Mark J Monaghan; Denisa Muraru; Kofo O Ogunyankin; Seung Woo Park; Ricardo E Ronderos; Anita Sadeghpour; Gregory M Scalia; Masaaki Takeuchi; Wendy Tsang; Edwin S Tucay; Ana Clara Tude Rodrigues; Amuthan Vivekanandan; Yun Zhang; Marcus Schreckenberg; Michael Blankenhagen; Markus Degel; Alexander Rossmanith; Victor Mor-Avi; Federico M Asch; Roberto M Lang Journal: J Am Soc Echocardiogr Date: 2021-05-25 Impact factor: 7.722