Literature DB >> 22358249

A combined minimally invasive approach for the treatment of aortoesophageal fistula caused by the ingestion of a chicken bone: case report and literature review.

Xiaodong Chen1, Jianwen Li, Jie Chen, Yu Zhou, Yuanqi Zhang, Hongfei Ding, Shuichuan Huang, Zhi Zhang.   

Abstract

Entities:  

Mesh:

Year:  2012        PMID: 22358249      PMCID: PMC3275129          DOI: 10.6061/clinics/2012(02)19

Source DB:  PubMed          Journal:  Clinics (Sao Paulo)        ISSN: 1807-5932            Impact factor:   2.365


× No keyword cloud information.

INTRODUCTION

Aortoesophageal fistula (AEF) is a rare, catastrophic complication that can be caused by the ingestion of a foreign body (1,2). In the past, AEF was treated with surgical repair using thoracic esophagectomy and esophagogastrostomy. However, the mortality rate for patients with AEF remains extremely high (2-4). Recently, we successfully treated a patient with AEF that was caused by the ingestion of a chicken bone. We placed an aortic endovascular stent graft followed by thoracoscopic mediastinal debridement and drainage. A retrievable esophageal stent was placed to isolate the fistula, which was removed after 80 days. In this report, we present our experience using a combined minimally invasive therapeutic approach for the treatment of AEF.

CASE DESCRIPTION

A 22-year-old man was admitted to our hospital on March 28, 2011 complaining of seven days of retrosternal discomfort and a single episode of vomiting of approximately 50 mL of fresh red blood. The patient had swallowed a chicken bone prior to the onset of the discomfort. His vital signs were stable during physical examination, and there was no fever on arrival at the hospital. Laboratory findings revealed a white blood cell (WBC) count of 19.9×109/L and hemoglobin (Hb) levels of 84 g/L. He vomited approximately 300 ml of bright red blood and produced a large amount of tarry stool on March 29, 2011. His Hb levels subsequently decreased to 73 g/L. CT angiography (CTA) demonstrated a mediastinal esophageal fistula with inflammatory exudate surrounding the descending aorta. An aortic pseudoaneurysm at the anterior wall of the descending aorta was also observed at the lower edge of thoracic vertebrate 5 (Figure 1). A diagnosis of AEF was highly suspected. Angiography was performed on March 31, 2011 and showed a 0.7 cm×0.4 cm pseudoaneurysm of the descending aorta approximately 4.5 cm below the origin of the left subclavian artery, which was consistent with the results of the CTA. This finding confirmed the diagnosis of AEF. After an immediate multidisciplinary discussion, a plan for definitive treatment was established. An endovascular stent-graft (catalog number: TF2424C200X, Medtronic, Inc., USA) was placed inside the descending aorta to isolate the pseudoaneurysm. Postoperative angiography showed satisfactory exclusion results, and the patient was transferred to the operating room for thoracoscopic exploration. Swelling in the esophageal bed and inflammatory exudates were observed under the thoracoscope. Immediate mediastinal debridement and irrigation was performed using the thoracoscope. Two F16 silicone tubes were placed in the pleural cavity and the mediastinum to facilitate postoperative drainage. The patient underwent an esophageal endoscopy, and an esophageal fistula approximately 1.0 cm in diameter was found 25 cm away from the incisors (Figure 2A). A single-use retrievable esophageal stent-graft (Micro-Tech Co., Ltd. Nanjing China, length 8.0 cm, diameter 2.0 cm) was implanted to isolate the esophageal perforation followed by the placement of a three-lumen gastrojejunal tube for additional enteral nutrition. After spending three days in the intensive care unit (ICU), the patient was transferred back to our department. He had no melena and no fever or vomiting, and the mediastinal and pleural drainage gradually became clear. On the 7th day after the operation, esophageal imaging with meglumine diatrizoate showed no leakage, and the three-lumen gastrojejunal tube was removed. The patient was provided with a liquid diet. Both of the drainage tubes in the pleural cavity and the mediastinum were removed 25 days after the operation. Repeat CTA confirmed successful tamponade of the fistula 40 days after the operation (Figure 3). Antibiotic treatment was administered during hospitalization. Laboratory findings showed that the patient's WBC count was 23.0×109/mL with 79.1% neutrophils (NEs) on the second day after the operation. The WBC count and NE returned to normal after 14 consecutive days of administration of the antibiotic meropenem based on cultures of the mediastinal exudates, which were positive for Pseudomonas aeruginosa seven days after the operation. The patient was switched to oral antibiotics and discharged on May 18, 2011. He was re-admitted to remove the esophageal stent 80 days after the operation. Esophageal endoscopy revealed a complete healing of the original fistula after removal of the esophageal stent (Figure 2B). No fever was observed during the treatment follow-up. After continuous administration of oral antibiotics for three months, the patient stopped the medication when blood laboratory findings and chest X-ray results were normal. The patient lived a normal life during six months of follow-up after the operation.
Figure 1

CT angiography images. A) Mediastinal esophageal fistula with inflammatory exudate surrounding the descending aorta (arrow). B) An aortic pseudoaneurysm at the anterior wall of the descending aorta at the lower edge of thoracic vertebrae 5 (arrow).

Figure 2

Esophageal endoscopy. A) An esophageal fistula approximately 1.0 cm in diameter was found 25 cm away from the incisors prior to implantation of the esophageal stent (arrow). B) Complete healing of the original fistula after the removal of the esophageal stent (arrow).

Figure 3A

CT angiography confirmed successful tamponade of the fistula.

DISCUSSION

The widely accepted approach for treating AEFs caused by foreign bodies is a thoracotomy with aortic stent-graft interposition followed by reconstruction of the esophagus. However, this procedure has extremely high mortality and morbidity rates (4,5). The formidable challenges in treating these injuries are rupture of the AEF, mediastinal infection caused by esophageal perforation and endovascular stent-graft infection. Although several successful cases have been documented since the first AEF operation reported by Ctercteko (6) in 1980, the survival rate of patients with AEF has remained dismal. Zhang et al. (2) reported 32 cases of esophageal foreign body and/or aortoesophageal fistula between 1963 and 2010. Of 19 patients who underwent surgical interventions, three patients were completely cured and 16 patients died of fatal hemorrhage. The other 13 patients who were treated nonsurgically all died as a result of various treatments. The optimal management of AEFs remains controversial. With the rapid development of new endovascular techniques, endovascular aortic stent grafts have shown significant advantages over traditional open surgery for the treatment of aorta fistulas (1). Endovascular stent placement for AEF has been described with good results (3,7). Verhoeven et al. (1) suggested that endovascular aortic stent grafts should be considered as a first-choice lifesaving procedure. These grafts prevent fatal exsanguination and provide the valuable time necessary to optimize the patient's condition before proceeding with additional treatments. Postoperative infections due to the placement of aortic stents depends on the treatment of the esophageal fistula, mediastinal drainage and anti-infection treatments. Esophageal exclusion with mediastinal drainage followed by secondary esophageal reconstruction was previously a standard surgical approach for the treatment of esophageal fistulas. However, this procedure is time consuming and can cause significant surgical trauma. Thoracoscopy is a minimally invasive technique for managing mediastinal and thoracic diseases (8,9). Esophageal stents are universally applied to treat stenosis of the esophagus and esophageal perforation (10,11). We used thoracoscopy instead of mediastinal debridement, irrigation and drainage. We implanted retrievable esophageal stents and placed a three-lumen gastrojejunal tube. Esophageal stents avoid saliva and/or exudates passing through the esophageal fistula into the mediastinum to prevent mediastinal infection. In this case, we chose a removable esophageal stent because the patient was a young man with benign esophageal disease. The three-lumen gastrojejunal tube ensured early postoperative intake of nutrients. After removal of the three-lumen gastrojejunal tube on postoperative day 7, the patient was provided with a liquid diet for nutritional support. This report represents the first case in which the minimally invasive approaches described were combined to successfully treat a patient with AEF. Based on our limited experiences, we suggest performing aortic endovascular repair by stent-graft to ultimately reduce the risk of aortic rupture, followed by thoracoscopy to treat mediastinal infections and placement of a retrievable esophageal stent in patients with AEF who have slight inflammation or perforation of the esophageal region and surrounding tissues. The combined approach resulted in less trauma and a more rapid recovery compared to conventional thoracotomy. This minimally invasive approach may be a safe and feasible method for treating patients with AEF and has the potential for improved treatment options for AEFs. A larger sample size and long-term follow-up of patients with AEFs will be required to further evaluate the feasibility of this novel combined approach.

ACKNOWLEDGMENTS

We would like to thank Prof. Wenjian Wang and Xun Hou, PhD of the First Affiliated Hospital of Sun Yat-sen University for editing the manuscript.
  11 in total

1.  Diagnosis and treatment of 32 cases with aortoesophageal fistula due to esophageal foreign body.

Authors:  Xiaoli Zhang; Jiajia Liu; Jingjia Li; Jianguo Hu; Fenglei Yu; Shunnong Li; Xinming Yang
Journal:  Laryngoscope       Date:  2011-01-13       Impact factor: 3.325

Review 2.  Aortoesophageal fistula: alternatives of treatment case report and literature review.

Authors:  Jorge Flores; Norihiko Shiiya; Takashi Kunihara; Kimihiro Yoshimoto; Keishu Yasuda
Journal:  Ann Thorac Cardiovasc Surg       Date:  2004-08       Impact factor: 1.520

3.  The use of a self-expandable plastic stent for an iatrogenic esophageal perforation.

Authors:  John M Petersen
Journal:  Gastroenterol Hepatol (N Y)       Date:  2010-06

4.  Successful treatment for descending necrotizing mediastinitis with severe thoracic emphysema using video-assisted thoracoscopic surgery.

Authors:  Akihito Kozuki; Hiroharu Shinozaki; Atsushi Tajima; Kenichi Kase
Journal:  Gen Thorac Cardiovasc Surg       Date:  2010-11-11

5.  Thoracic endovascular aortic repair for aortobronchial or aortoesophageal fistulas: permanent or temporary salvage or not an option at all?

Authors:  Eric L Verhoeven; George Vourliotakis
Journal:  J Endovasc Ther       Date:  2009-08       Impact factor: 3.487

Review 6.  Aortoesophageal fistula caused by aneurysm of the thoracic aorta: successful surgical treatment, case report, and literature review.

Authors:  E S da Silva; F L Tozzi; J P Otochi; E M de Tolosa; C R Neves; F Fortes
Journal:  J Vasc Surg       Date:  1999-12       Impact factor: 4.268

7.  Aortoesophageal fistula successfully treated by endovascular stent-graft.

Authors:  Roderik Metz; A Nikola Kimmings; Hence J M Verhagen; Inne H M Borel Rinkes; Richard van Hillegersberg
Journal:  Ann Thorac Surg       Date:  2006-09       Impact factor: 4.330

8.  Use of a fully covered self-expandable metal stent for the treatment of benign esophageal diseases.

Authors:  Johan C Bakken; Louis M Wong Kee Song; Piet C de Groen; Todd H Baron
Journal:  Gastrointest Endosc       Date:  2010-10       Impact factor: 9.427

9.  Aorta-esophageal fistula induced by a foreign body: the first recorded survival.

Authors:  G Ctercteko; C K Mok
Journal:  J Thorac Cardiovasc Surg       Date:  1980-08       Impact factor: 5.209

10.  Acute management of aortobronchial and aortoesophageal fistulas using thoracic endovascular aortic repair.

Authors:  Frederik H W Jonker; Robin Heijmen; Santi Trimarchi; Hence J M Verhagen; Frans L Moll; Bart E Muhs
Journal:  J Vasc Surg       Date:  2009-05-29       Impact factor: 4.268

View more
  8 in total

1.  Proposed management protocol for ingested esophageal foreign body and aortoesophageal fistula: a single-center experience.

Authors:  Yiping Wei; Liru Chen; Yiming Wang; Dongliang Yu; Jinhua Peng; Jianjun Xu
Journal:  Int J Clin Exp Med       Date:  2015-01-15

2.  Surgical treatment of aortoesophageal fistula induced by a foreign body in the esophagus: 40 years of experience at a single hospital.

Authors:  Er-Ping Xi; Jian Zhu; Shui-Bo Zhu; Yong Liu; Gui-Lin Yin; Yu Zhang; Xiao-Ming Zhang; Yong-Qiang Dong
Journal:  Surg Endosc       Date:  2013-03-26       Impact factor: 4.584

3.  Aorto-esophageal fistula caused by fishbone ingestion: a case report on staged endovascular and endoscopic treatment.

Authors:  Yu-Yan Zhang; Shan Li; Xiang-Lei Yuan; Bing Hu
Journal:  BMC Gastroenterol       Date:  2021-02-02       Impact factor: 3.067

4.  Endoscopic extraction of a submucosal esophageal foreign body piercing into the thoracic aorta: A case report.

Authors:  Zhi-Cao Chen; Gui-Quan Chen; Xiao-Chun Chen; Chang-Ye Zheng; Wei-Dong Cao; Gang-Hao Deng
Journal:  World J Clin Cases       Date:  2022-03-16       Impact factor: 1.337

5.  Surgical approach for the treatment of aortoesophageal fistula combined with dual aortic aneurysms: a case report.

Authors:  Rihao Xu; Tiance Wang; Dan Li; Zhicheng Zhu; Shudong Zhang; Chengluan Xuan; Wen Yan; Kexiang Liu
Journal:  J Cardiothorac Surg       Date:  2013-11-04       Impact factor: 1.637

6.  Aortic Pseudoaneurysm Secondary to Mediastinitis due to Esophageal Perforation.

Authors:  Claudia Patricia Zuluaga; Felipe Aluja Jaramillo; Sergio Andrés Velásquez Castaño; Aura Lucía Rivera Bernal; Julio Cesar Granada; Jorge Alberto Carrillo Bayona
Journal:  Case Rep Radiol       Date:  2016-02-10

7.  Aortic injury caused by esophageal foreign body-case reports of 3 patients and literature review.

Authors:  Liping Zeng; Wenbo Shu; Honghai Ma; Jian Hu
Journal:  Medicine (Baltimore)       Date:  2020-06-26       Impact factor: 1.817

8.  Endovascular stent-graft treatment for aortoesophageal fistula induced by an esophageal fishbone: Two cases report.

Authors:  Hang Gong; Wei Wei; Zhong Huang; Ying Hu; Xian-Li Liu; Zhen Hu
Journal:  World J Clin Cases       Date:  2022-03-06       Impact factor: 1.337

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.