Literature DB >> 22357995

Chest radiography in the ICU: Part 2, Evaluation of cardiovascular lines and other devices.

Myrna C B Godoy1, Barry S Leitman, Patricia M de Groot, Ioannis Vlahos, David P Naidich.   

Abstract

OBJECTIVE: In this pictorial essay, we discuss and illustrate normal and aberrant positioning of the cardiovascular support and monitoring devices frequently used in critically ill patients, including central venous catheters, pulmonary artery catheters, left atrial catheters, transvenous pacemakers, automatic implantable cardioverter defibrillators, intraaortic counterpulsation balloon pump, and ventricular assist devices, as well as their inherent complications.
CONCLUSION: The radiographic evaluation of the support and monitoring devices used in patients in the ICU is important, because the potentially serious complications arising from their introduction and use are often not clinically apparent. Familiarity with normal and abnormal radiographic findings is critical for the detection of these complications.

Entities:  

Mesh:

Year:  2012        PMID: 22357995     DOI: 10.2214/AJR.11.8124

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Evaluation of medical devices in thoracic radiograms in intensive care unit - time to pay attention!

Authors:  Ana Sofia Linhares Moreira; Maria da Graça Alves Afonso; Mónica Ribeiro Dos Santos Alves Dinis; Maria Cristina Granja Teixeira Dos Santos
Journal:  Rev Bras Ter Intensiva       Date:  2016-09

2.  Can portable tomosynthesis improve the diagnostic value of bedside chest X-ray in the intensive care unit? A proof of concept study.

Authors:  Jeroen Cant; Annemie Snoeckx; Gert Behiels; Paul M Parizel; Jan Sijbers
Journal:  Eur Radiol Exp       Date:  2017-10-27

Review 3.  Central Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction.

Authors:  Carlos J Roldan; Linda Paniagua
Journal:  West J Emerg Med       Date:  2015-10-20

Review 4.  Chest radiographs of cardiac devices (Part 1): Lines, tubes, non-cardiac medical devices and materials.

Authors:  Rishi P Mathew; Timothy Alexander; Vimal Patel; Gavin Low
Journal:  SA J Radiol       Date:  2019-07-29

5.  Malpositioned Lines and Tubes on Chest Radiograph - A Concise Pictorial Review.

Authors:  Muthu Kumar Sakthivel; Thangavijayan Bosemani; Leon Bacchus; Ertan Pamuklar
Journal:  J Clin Imaging Sci       Date:  2020-10-22

6.  Chest radiographs of cardiac devices (Part 1): Cardiovascular implantable electronic devices, cardiac valve prostheses and Amplatzer occluder devices.

Authors:  Rishi P Mathew; Timothy Alexander; Vimal Patel; Gavin Low
Journal:  SA J Radiol       Date:  2019-07-31
  6 in total