Literature DB >> 22356771

Pulse compression technique for simultaneous HIFU surgery and ultrasonic imaging: a preliminary study.

Jong Seob Jeong1, Jin Ho Chang, K Kirk Shung.   

Abstract

In an ultrasound image-guided High Intensity Focused Ultrasound (HIFU) surgery, reflected HIFU waves received by an imaging transducer should be suppressed for real-time simultaneous imaging and therapy. In this paper, we investigate the feasibility of pulse compression scheme combined with notch filtering in order to minimize these HIFU interference signals. A chirp signal modulated by the Dolph-Chebyshev window with 3-9MHz frequency sweep range is used for B-mode imaging and 4MHz continuous wave is used for HIFU. The second order infinite impulse response notch filters are employed to suppress reflected HIFU waves whose center frequencies are 4MHz and 8MHz. The prototype integrated HIFU/imaging transducer that composed of three rectangular elements with a spherically con-focused aperture was fabricated. The center element has the ability to transmit and receive 6MHz imaging signals and two outer elements are only used for transmitting 4MHz continuous HIFU wave. When the chirp signal and 4MHz HIFU wave are simultaneously transmitted to the target, the reflected chirp signals mixed with 4MHz and 8MHz HIFU waves are detected by the imaging transducer. After the application of notch filtering with pulse compression process, HIFU interference waves in this mixed signal are significantly reduced while maintaining original imaging signal. In the single scanline test using a strong reflector, the amplitude of the reflected HIFU wave is reduced to -45dB. In vitro test, with a sliced porcine muscle shows that the speckle pattern of the restored B-mode image is close to that of the original image. These preliminary results demonstrate the potential for the pulse compression scheme with notch filtering to achieve real-time ultrasound image-guided HIFU surgery.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22356771      PMCID: PMC3751008          DOI: 10.1016/j.ultras.2012.01.016

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  17 in total

1.  Noninvasive surgery of prostate tissue by high intensity focused ultrasound: an updated report.

Authors:  N T Sanghvi; R S Foster; R Bihrle; R Casey; T Uchida; M H Phillips; J Syrus; A V Zaitsev; K W Marich; F J Fry
Journal:  Eur J Ultrasound       Date:  1999-03

2.  Elastography for the follow-up of high-intensity focused ultrasound prostate cancer treatment: initial comparison with MRI.

Authors:  L Curiel; R Souchon; O Rouvière; A Gelet; J Y Chapelon
Journal:  Ultrasound Med Biol       Date:  2005-11       Impact factor: 2.998

Review 3.  Use of modulated excitation signals in medical ultrasound. Part I: Basic concepts and expected benefits.

Authors:  Thanassis Misaridis; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

4.  A method to synchronize high-intensity, focused ultrasound with an arbitrary ultrasound imager.

Authors:  Neil R Owen; Michael R Bailey; James Hossack; Lawrence A Crum
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-03       Impact factor: 2.725

5.  Coded excitation system for improving the penetration of real-time phased-array imaging systems.

Authors:  M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

6.  In vivo monitoring of focused ultrasound surgery using local harmonic motion.

Authors:  Laura Curiel; Rajiv Chopra; Kullervo Hynynen
Journal:  Ultrasound Med Biol       Date:  2008-09-21       Impact factor: 2.998

7.  Adaptive HIFU noise cancellation for simultaneous therapy and imaging using an integrated HIFU/imaging transducer.

Authors:  Jong Seob Jeong; Jonathan Matthew Cannata; K Kirk Shung
Journal:  Phys Med Biol       Date:  2010-03-12       Impact factor: 3.609

Review 8.  High-intensity focused ultrasound for the treatment of localized prostate cancer: 5-year experience.

Authors:  Andreas Blana; Bernhard Walter; Sebastian Rogenhofer; Wolf F Wieland
Journal:  Urology       Date:  2004-02       Impact factor: 2.649

9.  Using the acoustic interference pattern to locate the focus of a high-intensity focused ultrasound (HIFU) transducer.

Authors:  Chih-Ching Wu; Chiung-Nien Chen; Ming-Chih Ho; Wen-Shiang Chen; Po-Huang Lee
Journal:  Ultrasound Med Biol       Date:  2007-08-27       Impact factor: 2.998

10.  Ultrasound transducer and system for real-time simultaneous therapy and diagnosis for noninvasive surgery of prostate tissue.

Authors:  Jong Seob Jeong; Jin Ho Chang; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-09       Impact factor: 2.725

View more
  3 in total

Review 1.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

2.  FUS-Net: U-Net-Based FUS Interference Filtering.

Authors:  Stephen A Lee; Elisa E Konofagou
Journal:  IEEE Trans Med Imaging       Date:  2022-04-01       Impact factor: 10.048

Review 3.  Design and Challenges of Sonodynamic Therapy System for Cancer Theranostics: From Equipment to Sensitizers.

Authors:  Zhuoran Gong; Zhifei Dai
Journal:  Adv Sci (Weinh)       Date:  2021-03-12       Impact factor: 16.806

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.