Literature DB >> 22353667

Computational flow dynamics and preclinical assessment of a novel hemodialysis catheter.

Timothy W I Clark1, Koen Van Canneyt, Pascal Verdonck.   

Abstract

We examined flow characteristics and recirculation of a novel dialysis catheter with helically contoured lumens, which optimize the vectors of blood entering and leaving the device. Computational flow dynamics were used to measure shear stress, residence time (RT), Platelet Lysis Index (PLI), and recirculation of the study catheter, termed the VectorFlow catheter, compared with the Palindrome catheter. Bench and animal models were used to measure recirculation compared with other dialysis catheter designs. The VectorFlow catheter was associated with an 18% reduction in mean shear stress compared with the Palindrome catheter, at 13.6 and 16.6 Pa, respectively. Low PLI was seen with the VectorFlow (PLI = 0.019) and Palindrome (PLI = 0.015) catheters. The VectorFlow catheter was associated with a % RT >0.030 seconds of 1.2%, compared to 0.9% for the Palindrome. Calculated recirculation of the VectorFlow, Palindrome, and step-tip catheter designs in reversed position were 1.2 × 10(-4) %, 0.039%, and 13.6%, respectively. In vitro, the VectorFlow catheter had no detectable recirculation (0%) compared to 7.3-9.5% with the Palindrome at flow rates of 400-600 ml/minute. In vivo, the VectorFlow catheter had no detectable recirculation, compared to 6.7-12% for the Palindrome. The VectorFlow catheter was associated with an absence of detectable recirculation with favorable flow dynamics.
© 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22353667     DOI: 10.1111/j.1525-139X.2012.01052.x

Source DB:  PubMed          Journal:  Semin Dial        ISSN: 0894-0959            Impact factor:   3.455


  3 in total

1.  Computational fluid dynamics of ventricular catheters used for the treatment of hydrocephalus: a 3D analysis.

Authors:  Marcelo Galarza; Ángel Giménez; José Valero; Olga Porcar Pellicer; José María Amigó
Journal:  Childs Nerv Syst       Date:  2013-07-24       Impact factor: 1.475

2.  Clinical and Regulatory Considerations for Central Venous Catheters for Hemodialysis.

Authors:  Douglas M Silverstein; Scott O Trerotola; Timothy Clark; Garth James; Wing Ng; Amy Dwyer; Marius C Florescu; Roman Shingarev; Stephen R Ash
Journal:  Clin J Am Soc Nephrol       Date:  2018-10-11       Impact factor: 8.237

Review 3.  Biophysics of biofilm infection.

Authors:  Philip S Stewart
Journal:  Pathog Dis       Date:  2014-01-16       Impact factor: 3.166

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.