Literature DB >> 2235301

Accelerations due to impact at heel strike using below-knee prosthesis.

H W Van Jaarsveld1, H J Grootenboer, J De Vries.   

Abstract

The acceleration in the sagittal plane of the prosthetic tube at heel strike in normal walking was measured in five healthy amputees with their definitive below-knee prosthesis, every subject using six different prosthetic feet, wearing sport shoes as well as leather shoes. The experiments were carried out in the rehabilitation centre "Het Roessingh", Enschede, The Netherlands. Maximum accelerations were extracted from the acceleration-time-signal. Mean acceleration maxima of all subjects were calculated for each foot-shoe combination to eliminate the individual influence of the subjects. In the axial direction the maximal accelerations demonstrate a clear difference among the prosthetic feet and the shoes, while in dorsoventral (tangential) direction the inter-individual variation in the acceleration extremes dominates the difference between the types of footwear. In comparison with non-amputees the magnitude of the maximal axial acceleration at heel strike does not differ significantly.

Mesh:

Year:  1990        PMID: 2235301     DOI: 10.3109/03093649009080323

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  4 in total

1.  The effects of increased prosthetic ankle motions on the gait of persons with bilateral transtibial amputations.

Authors:  Po-Fu Su; Steven A Gard; Robert D Lipschutz; Todd A Kuiken
Journal:  Am J Phys Med Rehabil       Date:  2010-01       Impact factor: 2.159

2.  Effect of prosthetic ankle units on roll-over shape characteristics during walking in persons with bilateral transtibial amputations.

Authors:  Steven A Gard; Po-Fu Su; Robert D Lipschutz; Andrew H Hansen
Journal:  J Rehabil Res Dev       Date:  2011

3.  Gait symmetry and regularity in transfemoral amputees assessed by trunk accelerations.

Authors:  Andrea Tura; Michele Raggi; Laura Rocchi; Andrea G Cutti; Lorenzo Chiari
Journal:  J Neuroeng Rehabil       Date:  2010-01-19       Impact factor: 4.262

4.  Adapting Semi-Active Prostheses to Real-World Movements: Sensing and Controlling the Dynamic Mean Ankle Moment Arm with a Variable-Stiffness Foot on Ramps and Stairs.

Authors:  Jennifer K Leestma; Katherine Heidi Fehr; Peter G Adamczyk
Journal:  Sensors (Basel)       Date:  2021-09-08       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.