Literature DB >> 22350241

Effectiveness and safety of minilaparoscopy-guided spleen biopsy: a retrospective series of 57 cases.

Tobias Werner1, Johannes Koch, Christian Frenzel, Ansgar W Lohse, Ulrike W Denzer.   

Abstract

BACKGROUND: Minilaparoscopy is an accepted method for liver biopsy. We report our experience with minilaparoscopy for splenic biopsy.
METHODS: We reviewed the records of all minilaparoscopy procedures performed from 1996 to 2004 at the University of Mainz Medical Center and from 2005 to mid-2011 at the University of Hamburg Medical Center to identify patients who underwent a minilaparoscopy-guided splenic biopsy. All procedures were performed using the previously described method (2.75-mm trocar, 2.3-mm Veress needle, 1.9-mm laparoscope) with the patient under conscious sedation (midazolam/meperidine/propofol). Splenic biopsies were performed using a second trocar with an 18-G Tru-Cut needle. Argon plasma coagulation (APC) and/or fibrin glue (FG) were used to control postbiopsy bleeding.
RESULTS: Fifty-seven patients underwent minilaparoscopy-guided biopsy of the spleen (27 females, 30 males; median age = 41 years, range = 16-76). A specimen suitable for histopathologic evaluation was obtained in all patients. Grouped by preprocedure indication, a definitive diagnosis was obtained in 70% (7/10) of patients who had splenic mass lesions in prior imaging (3 B-NHL, 2 hemangioma, 1 tuberculosis, 1 sarcoidosis; p < 0.01) compared to 29% (10/34) in the group with unexplained fever or suspected lymphoma (3 tuberculosis, 2 B-NHL, 1 hepatosplenic T-cell lymphoma, 1 sarcoidosis, 1 Still's disease, 1 EBV, 1 Q-fever) and 0/13 with unexplained splenomegaly. Focal lesions noted at laparoscopy yielded to a histologic diagnosis in 38% (11/29) of 42 patients compared to 21% (6/28) without laparoscopic abnormality (p = 0.25). Bleeding from the biopsy site was noted in 96.5% (55/57) and was classified as brisk in 9. Control of hemorrhage was achieved in all patients (APC: 47, FG: 1, APC/FG: 7). There was no postprocedure bleeding or other complications.
CONCLUSION: Splenic biopsy guided by minilaparoscopy can be performed safely. Postprocedure bleeding is readily controlled with APC with or without fibrin glue. The highest diagnostic yield is in patients with focal splenic lesions.

Entities:  

Mesh:

Year:  2012        PMID: 22350241     DOI: 10.1007/s00464-012-2190-y

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  23 in total

Review 1.  Diagnostic laparoscopy.

Authors:  J F Riemann
Journal:  Endoscopy       Date:  2003-01       Impact factor: 10.093

2.  Fever of unexplained origin: report on 100 cases.

Authors:  R G PETERSDORF; P B BEESON
Journal:  Medicine (Baltimore)       Date:  1961-02       Impact factor: 1.889

3.  [Mini laparoscopy].

Authors:  U W Denzer; A W Lohse
Journal:  Dtsch Med Wochenschr       Date:  2008-07       Impact factor: 0.628

4.  Ultrasonically guided staging splenic tissue core biopsy in patients with non-Hodgkin's lymphoma.

Authors:  T Suzuki; H Shibuya; S Yoshimatsu; S Suzuki
Journal:  Cancer       Date:  1987-08-15       Impact factor: 6.860

5.  Prospective randomized comparison of minilaparoscopy and percutaneous liver biopsy: diagnosis of cirrhosis and complications.

Authors:  Ulrike Denzer; Andrea Arnoldy; Stefan Kanzler; Peter R Galle; Hans P Dienes; Ansgar W Lohse
Journal:  J Clin Gastroenterol       Date:  2007-01       Impact factor: 3.062

6.  Laparoscopic splenic biopsy.

Authors:  G Dagnini; M W Cladironi; G Marin; M Patella
Journal:  Endoscopy       Date:  1984-03       Impact factor: 10.093

7.  Percutaneous nonvascular splenic intervention: a 10-year review.

Authors:  Brian C Lucey; Giles W Boland; Michael M Maher; Peter F Hahn; Debra A Gervais; Peter R Mueller
Journal:  AJR Am J Roentgenol       Date:  2002-12       Impact factor: 3.959

8.  Diagnosis of liver cirrhosis: a comparison of modified ultrasound and laparoscopy in 100 consecutive patients.

Authors:  Uwe Weickert; Andrea Buttmann; Ralf Jakobs; Dieter Schilling; Axel Eickhoff; Jürgen Ferdinand Riemann
Journal:  J Clin Gastroenterol       Date:  2005-07       Impact factor: 3.062

9.  Ultrasound-guided fine needle biopsy of the spleen: high clinical efficacy and low risk in a multicenter Italian study.

Authors:  G Civardi; D Vallisa; R Bertè; A Giorgio; C Filice; M Caremani; E Caturelli; M Pompili; I De Sio; E Buscarini; L Cavanna
Journal:  Am J Hematol       Date:  2001-06       Impact factor: 10.047

10.  Minilaparoscopy in the diagnosis of peritoneal tumor spread: prospective controlled comparison with computed tomography.

Authors:  U Denzer; S Hoffmann; I Helmreich-Becker; H U Kauczor; M Thelen; S Kanzler; P R Galle; A W Lohse
Journal:  Surg Endosc       Date:  2004-05-27       Impact factor: 4.584

View more
  4 in total

Review 1.  Image-guided percutaneous splenic biopsy and drainage.

Authors:  Jennifer Sammon; Maria Twomey; Lee Crush; Michael M Maher; Owen J O'Connor
Journal:  Semin Intervent Radiol       Date:  2012-12       Impact factor: 1.513

2.  Feasibility and safety of minilaparoscopy-guided spleen biopsy.

Authors:  Yunqiang Cai; Xubao Liu
Journal:  Surg Endosc       Date:  2013-03-12       Impact factor: 4.584

3.  Ultrasound-guided percutaneous splenic biopsy using an 18-G core biopsy needle: our experience with 52 cases.

Authors:  Nirav Patel; Gemma Dawe; Ken Tung
Journal:  Br J Radiol       Date:  2015-09-04       Impact factor: 3.039

4.  Mini-laparoscopy as a diagnostic tool for abdominal tuberculosis: a retrospective series of 29 cases.

Authors:  Natascha Ndzedzeka-Völz; Thomas Theo Brehm; Malte Wehmeyer; Martin Christner; Till Sebastian Clauditz; Peter Hübener; Marylyn M Addo; Ansgar W Lohse; Stefan Schmiedel
Journal:  Surg Endosc       Date:  2022-10-13       Impact factor: 3.453

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.