Literature DB >> 22349345

Rapid analysis of caffeine in various coffee samples employing direct analysis in real-time ionization-high-resolution mass spectrometry.

Hana Danhelova1, Jaromir Hradecky, Sarka Prinosilova, Tomas Cajka, Katerina Riddellova, Lukas Vaclavik, Jana Hajslova.   

Abstract

The development and use of a fast method employing a direct analysis in real time (DART) ion source coupled to high-resolution time-of-flight mass spectrometry (TOFMS) for the quantitative analysis of caffeine in various coffee samples has been demonstrated in this study. A simple sample extraction procedure employing hot water was followed by direct, high-throughput (<1 min per run) examination of the extracts spread on a glass rod under optimized conditions of ambient mass spectrometry, without any prior chromatographic separation. For quantification of caffeine using DART-TOFMS, an external calibration was used. Isotopically labeled caffeine was used to compensate for the variations of the ion intensities of caffeine signal. Recoveries of the DART-TOFMS method were 97% for instant coffee at the spiking levels of 20 and 60 mg/g, respectively, while for roasted ground coffee, the obtained values were 106% and 107% at the spiking levels of 10 and 30 mg/g, respectively. The repeatability of the whole analytical procedure (expressed as relative standard deviation, RSD, %) was <5% for all tested spiking levels and matrices. Since the linearity range of the method was relatively narrow (two orders of magnitude), an optimization of sample dilution prior the DART-TOFMS measurement to avoid saturation of the detector was needed.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22349345     DOI: 10.1007/s00216-012-5820-2

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

1.  Multimodal Vacuum-Assisted Plasma Ion (VaPI) Source with Transmission Mode and Laser Ablation Sampling Capabilities.

Authors:  Joel D Keelor; Paul B Farnsworth; Arthur L Weber; Heather Abbott-Lyon; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2016-02-16       Impact factor: 3.109

2.  Identification of Drugs in Parenteral Pharmaceutical Preparations from a Quality Assurance and a Diversion Program by Direct Analysis in Real-Time AccuTOFTM-Mass Spectrometry (DART-MS).

Authors:  Justin L Poklis; Amanda J Mohs; Carl E Wolf; Alphonse Poklis; Michelle R Peace
Journal:  J Anal Toxicol       Date:  2016-07-29       Impact factor: 3.367

3.  Role of Coffee Caffeine and Chlorogenic Acids Adsorption to Polysaccharides with Impact on Brew Immunomodulation Effects.

Authors:  Cláudia P Passos; Rita M Costa; Sónia S Ferreira; Guido R Lopes; Maria T Cruz; Manuel A Coimbra
Journal:  Foods       Date:  2021-02-09

4.  Authenticity Assessment and Fraud Quantitation of Coffee Adulterated with Chicory, Barley, and Flours by Untargeted HPLC-UV-FLD Fingerprinting and Chemometrics.

Authors:  Nerea Núñez; Javier Saurina; Oscar Núñez
Journal:  Foods       Date:  2021-04-12

Review 5.  Bioactive micronutrients in coffee: recent analytical approaches for characterization and quantification.

Authors:  Abdulmumin A Nuhu
Journal:  ISRN Nutr       Date:  2014-01-22

6.  Direct analysis in real time-mass spectrometry for rapid quantification of five anti-arrhythmic drugs in human serum: application to therapeutic drug monitoring.

Authors:  Yuzhou Gui; Youli Lu; Shuijun Li; Mengqi Zhang; Xiaokun Duan; Charles C Liu; Jingying Jia; Gangyi Liu
Journal:  Sci Rep       Date:  2020-09-23       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.