Literature DB >> 22342152

Preliminary findings in quantification of changes in septal motion during follow-up of type B aortic dissections.

Christof Karmonik1, Cassidy Duran, Dipan J Shah, Javier E Anaya-Ayala, Mark G Davies, Alan B Lumsden, Jean Bismuth.   

Abstract

OBJECTIVE: To quantify longitudinal changes in intra-arterial septum (IS) motion with two-dimensional (2D) phase-contrast magnetic resonance imaging (2D pcMRI) in type B aortic dissections (AD) to improve the understanding of AD and its midterm development.
METHODS: From a database of 42 patients who underwent a dynamic magnetic resonance imaging (MRI) examination at the Acute Aortic Treatment Center of The Methodist DeBakey Heart & Vascular Center, 2D pcMRI image data was available from 10 patients with type B AD for both short-term (mean, 6.6 days; range, 1-10 days; n = 7) and midterm follow-up (mean, 155 days; range, 60-324; n = 5). IS motion was quantified as motion of IS boundary points averaged over the cardiac cycle. Relative change in IS motion was expressed as percent change compared with initial presentation. Maximum IS extension (true lumen [TL] expansion) and contraction (TL compression), IS fraction in phase with aortic flow and correlation of IS motion with aortic flow (IS compliance) were quantified.
RESULTS: IS motion at initial presentation was 0.68 ± 0.2 mm and was reduced at short-term (0.48 ± 0.3 mm; P = .07) and midterm (0.5 ± 0.2 mm; P = .1) follow-up. Trend in relative change of IS motion was variable during short-term follow-up: reduced in three subjects (-75% ± 6%) and elevated in four subjects (48% ± 23%). During midterm follow-up, relative change in IS motion was reduced in four subjects (28% ± 19%) and slightly elevated in one (6.2%). IS contraction decreased with follow-up while IS extension slightly increased. Fraction of IS moving in phase with aortic flow increased but IS compliance decreased, suggesting increasing IS stiffness.
CONCLUSIONS: Reduction of IS motion in AD is seen with short-term and midterm follow-up. Intersubject variability of this trend is high at short-term follow-up but low at midterm follow-up. Detailed analysis of IS motion parameters indicate reduction of IS contraction and IS compliance with time. This has potential implications for endovascular management of type B aortic dissections, as expansion of aortic stent grafts can be limited by a stiff IS.
Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22342152     DOI: 10.1016/j.jvs.2011.10.127

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  7 in total

1.  Distinguishing acute from chronic aortic dissections using CT imaging features.

Authors:  Norman A Orabi; Leslie E Quint; Kuanwong Watcharotone; Bin Nan; David M Williams; Karen M Kim
Journal:  Int J Cardiovasc Imaging       Date:  2018-06-18       Impact factor: 2.357

2.  Fluid-Structure Interaction Simulations of Repaired Type A Aortic Dissection: a Comprehensive Comparison With Rigid Wall Models.

Authors:  Yu Zhu; Saeed Mirsadraee; Ulrich Rosendahl; John Pepper; Xiao Yun Xu
Journal:  Front Physiol       Date:  2022-06-14       Impact factor: 4.755

3.  Efficacy of thoracic endovascular stent repair for chronic type B aortic dissection with aneurysmal degeneration.

Authors:  Salvatore T Scali; Robert J Feezor; Catherine K Chang; David H Stone; Philip J Hess; Tomas D Martin; Thomas S Huber; Adam W Beck
Journal:  J Vasc Surg       Date:  2013-04-03       Impact factor: 4.268

4.  Aortic dissection simulation models for clinical support: fluid-structure interaction vs. rigid wall models.

Authors:  Mona Alimohammadi; Joseph M Sherwood; Morad Karimpour; Obiekezie Agu; Stavroula Balabani; Vanessa Díaz-Zuccarini
Journal:  Biomed Eng Online       Date:  2015-04-15       Impact factor: 2.819

5.  High intimal flap mobility assessed by intravascular ultrasound is associated with better short-term results after TEVAR in chronic aortic dissection.

Authors:  Julia Lortz; Maria Papathanasiou; Christos Rammos; Martin Steinmetz; Alexander Lind; Konstantinos Tsagakis; Thomas Schlosser; Heinz Jakob; Tienush Rassaf; Rolf Alexander Jánosi
Journal:  Sci Rep       Date:  2019-05-13       Impact factor: 4.379

6.  An in vitro Assessment of the Haemodynamic Features Occurring Within the True and False Lumens Separated by a Dissection Flap for a Patient-Specific Type B Aortic Dissection.

Authors:  Liam Morris; Paul Tierney; Niamh Hynes; Sherif Sultan
Journal:  Front Cardiovasc Med       Date:  2022-03-17

7.  The effect of beta-blockers on hemodynamic parameters in patient-specific blood flow simulations of type-B aortic dissection: a virtual study.

Authors:  Mohammad Amin Abazari; Deniz Rafieianzab; M Soltani; Mona Alimohammadi
Journal:  Sci Rep       Date:  2021-08-06       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.