Interchangeability of activated clotting time values across different point-of-care systems.

Thenappan Thenappan1, Rajiv Swamy, Atman Shah, Sandeep Nathan, Jearlyn Nichols, Linda Bond, Neeraj Jolly.   

Abstract

Significant variability in activated clotting time (ACT) measurement exists based on the type of point-of-care system used. We sought to determine the degree of agreement in ACT measurements by the Hemochron Response and the Hemochron Signature Elite Whole Blood coagulation systems and whether these 2 systems can be used interchangeably. We prospectively compared 126-paired samples in 77 patients undergoing percutaneous coronary intervention. ACT was measured for each sample using the Hemochron Response system with glass test tubes and the Hemochron Signature Elite system with low-range ACT cuvettes simultaneously. We used correlation and Bland-Altman analyses. Mean age of the study cohort was 67 ± 11 years, 49% were women, and 65% of measurements were made after systemic anticoagulation. There was a significant correlation between the Hemochron Response and Hemochron Signature Elite systems (r = 0.84, p <0.01). However, the mean bias for the ACT measurement was 9 seconds (95% confidence interval -69 to 86). In the therapeutic range of ACT measurements, the mean bias was 15 seconds (95% confidence interval -60 to 91). Thirty-three percent of total samples had >10% disagreement and 8% of samples had >20% disagreement in the ACTs measured with the Hemochron Response compared to the Hemochron Signature Elite. In conclusion, the Hemochron Response and Hemochron Signature Elite ACT values cannot be used interchangeably. Institutions using these 2 devices should be cognizant of this difference for ensuring patient safety.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22341924     DOI: 10.1016/j.amjcard.2011.12.033

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Report from AmSECT's International Consortium for Evidence- Based Perfusion Consensus Statement: Minimal Criteria for Reporting Cardiopulmonary Bypass-Related Contributions to Red Blood Cell Transfusions Associated With Adult Cardiac Surgery.

Authors:  Donald S Likosky; Robert A Baker; Timothy A Dickinson; Daniel J FitzGerald; M Filip De Somer; Robert C Groom; David FitzGerald; Kenneth G Shann; Michael Poullis; Bruce D Spiess; Karim Jabr; Mark T Lucas; James D Ferguson; Shahna L Bronson
Journal:  J Extra Corpor Technol       Date:  2015-06

2.  Transition from Hemochron Response to Hemochron Signature Elite Activated Clotting Time Devices in a Congenital Cardiac Surgery Practice.

Authors:  Gregory S Matte; Robert J Howe; Juan Ibla; Sirisha Emani; Sitaram M Emani
Journal:  J Extra Corpor Technol       Date:  2019-12

Review 3.  Uninterrupted DOACs Approach for Catheter Ablation of Atrial Fibrillation: Do DOACs Levels Matter?

Authors:  Michael Hardy; Jonathan Douxfils; Anne-Sophie Dincq; Anne-Laure Sennesael; Olivier Xhaet; Francois Mullier; Sarah Lessire
Journal:  Front Cardiovasc Med       Date:  2022-03-29

Review 4.  Anticoagulation Management and Monitoring during Pediatric Extracorporeal Life Support: A Review of Current Issues.

Authors:  Lindsay M Ryerson; Laurence L Lequier
Journal:  Front Pediatr       Date:  2016-06-22       Impact factor: 3.418

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.