Literature DB >> 22341635

Increase in volume of ablation zones during follow-up is highly suggestive of ablation site recurrence in colorectal liver metastases treated with radiofrequency ablation.

Petra G Kele1, Koert P de Jong, Eric J van der Jagt.   

Abstract

PURPOSE: To test the hypothesis that volume changes of ablation zones (AZs) on successive computed tomography (CT) scans could predict ablation site recurrences (ASRs) in patients with colorectal liver metastases treated by radiofrequency (RF) ablation.
MATERIALS AND METHODS: RF ablation was performed in 58 patients with 117 metastases. Metastasis volumes and AZ volumes were measured before RF ablation, 1 week after RF ablation (t1), and every 3 months in the first year after RF ablation (t2-t5). Volumetry was performed semiautomatically on CT scans by drawing freehand regions of interest in the portal venous phase on 2-mm-thickness slices. ASR was defined as contrast enhancement on follow-up imaging or by a hot spot on fludeoxyglucose F 18 positron emission tomography combined with computed tomography (FDG-PET/CT) scanning. Proportional volume change of an AZ was defined as the difference in volume percentages between two successive time points of measurement. Negative values represented a volume decrease, and positive values represented a volume increase. Intraobserver variability and interobserver variability were evaluated by using intraclass correlation coefficients (ICCs).
RESULTS: ASRs occurred in 15 patients with 27 AZs. An increase in volume occurred in 26 AZs (96%) with ASRs. AZs without ASR showed no volume increase. Although proportional volume changes at t1-t2 were not predictive for ASR, subsequent volume changes were predictive for ASR. Contrast-enhanced CT-based evaluation detected ASRs in 17 (63%) of 27 AZs, 7 (26%) of 27 AZs were negative, and there was doubt in 3 (11%) of 27 AZs. Intraobserver variability and interobserver variability were good (0.998 [95% confidence interval [CI] 0.996-0.999; P < .001] and 0.993 [95% CI 0.987-0.996; P < .001]).
CONCLUSIONS: Volumetry of AZs is useful because a volume increase of an AZ during follow-up is highly suggestive of ASR. Negative volume changes of the AZ from t1-t2 were not correlated with the development of ASRs, but subsequent volume changes were predictive for ASRs.
Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22341635     DOI: 10.1016/j.jvir.2011.12.015

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  3 in total

1.  Diagnostic accuracy of 18F-FDG PET/CT for assessing response to radiofrequency ablation treatment in lung metastases: a multicentre prospective study.

Authors:  Françoise Bonichon; Jean Palussière; Yann Godbert; Marina Pulido; Edouard Descat; Anne Devillers; Catherine Meunier; Sophie Leboulleux; Thierry de Baère; Claire Galy-Lacour; Laurent Lagoarde-Segot; Anne-Laure Cazeau
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-09-17       Impact factor: 9.236

Review 2.  Radiofrequency ablation of liver tumors.

Authors:  Shaunagh McDermott; Debra A Gervais
Journal:  Semin Intervent Radiol       Date:  2013-03       Impact factor: 1.513

3.  Lack of Anatomical Concordance between Preablation and Postablation CT Images: A Risk Factor Related to Ablation Site Recurrence.

Authors:  Petra G Kele; Eric J Van der Jagt; Paul F M Krabbe; Koert P de Jong
Journal:  Int J Hepatol       Date:  2012-12-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.