Literature DB >> 22340537

Capillary electrochromatography-mass spectrometry determination of melamine and related triazine by-products using poly(divinyl benzene-alkene-vinylbenzyl trimethylammonium chloride) monolithic stationary phases.

Hsi-Ya Huang1, Cheng-Lan Lin, Shu-Huei Jiang, Brenda Singco, Yi-Jie Cheng.   

Abstract

In this study, a capillary electrochromatography (CEC) method coupled either with UV or mass spectrometric detection was developed for the detection of trace-amounts of melamine and its related by-products (ammeline, ammelide, and cyanuric acid). A series of poly(divinyl benzene-alkene-vinylbenzyl trimethylammonium chloride) monolithic columns, which were prepared by a simple in situ polymerization with divinyl benzene (DVB), vinylbenzyl trimethylammonium chloride (VBTA) and different types of alkene monomers such as 1-octene, 1-dodecene or 1-octadecene were used as separation columns, with the poly(DVB-1-dodecene-VBTA) monolith as the optimal chromatographic material because it provided a better separation. The detection limits of four melamine derivatives were in the ranged of 0.6-2.18 mg L(-1) by the optimal CEC-UV mode, and were reduced from 2.2 to 19.4 μg L(-1) by the optimal CEC-MS mode. Finally, the proposed CEC methods successfully determined melamine contaminations (0.1 mg L(-1) per analyte) in several dairy products as test samples with analyte recovery range of 69-85% (intra-day) and 68-75% (inter-day), and with peak area reproducibility range of 4.3-8.6% and 8.7-15.6% for intra-day and inter-day, respectively. This is the first report for CEC separation coupled with MS detection applied in trace melamine residue analyses with a faster separation and comparable or even better detection ability than previous GC-MS, CE-MS, as well as LC-MS methods.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Year:  2012        PMID: 22340537     DOI: 10.1016/j.aca.2011.12.073

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

Review 1.  Recent developments in the detection of melamine.

Authors:  Yuan Liu; Ewen E D Todd; Qiang Zhang; Jiang-rong Shi; Xian-jin Liu
Journal:  J Zhejiang Univ Sci B       Date:  2012-07       Impact factor: 3.066

2.  A simple magnetic solid-phase extraction method based on magnetite/graphene oxide nanocomposite for pre-concentration and determination of melamine by high-performance liquid chromatography.

Authors:  Hossein Abdolmohammad-Zadeh; Abbasali Zamani; Zahra Shamsi
Journal:  Environ Sci Pollut Res Int       Date:  2020-01-11       Impact factor: 4.223

3.  Capillary Electromigration Techniques Coupled to Mass Spectrometry: Applications to Food Analysis.

Authors:  Vijay D Patel; Shahab A Shamsi; K Sutherland
Journal:  Trends Analyt Chem       Date:  2021-02-25       Impact factor: 14.908

  3 in total