Literature DB >> 22339053

Placement of C-7 intralaminar screws: a quantitative anatomical and morphometric evaluation.

Mehmet Şenoğlu1, Fuat Özkan, Mustafa Çelik.   

Abstract

OBJECT: Crossing laminar screws at C-7 have been recently described as a method for the fixation of C-7. In this study the authors measured locations on axial CT scans to determine the feasibility of placing a screw in the C-7 lamina, and they evaluated the reliability of the surface of the dorsal arch of C-7 as a landmark for determining the optimal site of screw entry.
METHODS: A total of 207 axial CT scans of C-7 spines were evaluated, and 4 critical measurements were determined for screw entry points, trajectories, and lengths for placement of intralaminar screws.
RESULTS: The mean width of the right C-7 lamina was 5.9 mm (range 4.2-9.3 mm). The mean width of the left C-7 lamina was 6.0 mm (range 4.2-10.2 mm). The laminar width was too small (< 5.5 mm) in 37.7% of cases to accommodate a 3.5-mm diameter screw, given the desire for at least 1 mm of play on each side of the screw.
CONCLUSIONS: These measurements provide guidelines for operating on the posterior aspect of C-7 and enhance the confidence of the surgeon. Viewing the anatomy of the C-7 laminae in detail through preoperative CT scanning can greatly assist the surgeon in choosing the fixation method. The width of the C-7 lamina is sufficient for intralaminar screw placement in more than 60% of patients.

Entities:  

Mesh:

Year:  2012        PMID: 22339053     DOI: 10.3171/2012.1.SPINE111048

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  4 in total

1.  Morphological study of the posterior osseous structures of subaxial cervical spine in a population from northeastern China.

Authors:  Zhenyu Wang; Jiali Leng; Jianhua Liu; Yi Liu
Journal:  J Orthop Surg Res       Date:  2015-04-21       Impact factor: 2.359

2.  Laminar screw fixation in the subaxial cervical spine: A report on three cases.

Authors:  Hironori Tanabe; Yoichi Aota; Tomoyuki Saito
Journal:  World J Orthop       Date:  2016-10-18

3.  C7 intralaminar screw placement, an alternative to lateral mass or pedicle fixation for treatment of cervical spondylytic myelopathy, kyphotic deformity, and trauma: A case report and technical note.

Authors:  Michael T Koltz; Christopher M Maulucci; Charles A Sansur; D Kojo Hamilton
Journal:  Surg Neurol Int       Date:  2014-01-17

4.  Feasibility of bilateral crossing c7 intralaminar screws: a cadaveric study.

Authors:  Tae-Hyun Baek; Ilsup Kim; Jae-Taek Hong; Daniel H Kim; Dongsuk Shin; Sang-Won Lee
Journal:  J Korean Neurosurg Soc       Date:  2014-07-31
  4 in total