A cost analysis of reusable and disposable flexible optical scopes for intubation.

M F Tvede1, M S Kristensen, M Nyhus-Andreasen.   

Abstract

BACKGROUND: Intubation using a flexible optical scope (FOS) is a cornerstone technique for managing the predicted and unpredicted difficult airway. The term FOS covers both fibre-optic scopes and videoscopes. The total costs of using flexible scopes for intubation are unknown. The recent introduction of a disposable flexible scope for intubation merits closer scrutiny of the total costs associated with both modalities.
METHODS: The costs incurred during intubations using FOSs at a large anaesthesia department were identified, and a series of intubations using a disposable scope were analyzed for comparison. Recognized health-economic methodology was applied.
RESULTS: During a 1-year period, 360 FOS intubations were performed. In this clinical setting, the average cost of an intubation using a reusable FOS was €177.7. When using the disposable Ambu(®) aScope (Ambu A/S, Ballerup, Denmark), the cost was €204.4. The break-even point, i.e. the number of intubations per month where the cost of using disposable and non-disposable equipment is identical, was 22.5/month. A subgroup analysis looking solely at intubations performed with flexible videoscopes revealed that the cost per intubation was equal for disposable and reusable videoscopes.
CONCLUSION: At our institution, the total cost of an intubation is greater when using disposable compared with reusable equipment (€204.4 vs. €177.7). If video equipment with an external monitor is considered mandatory, the expenses are of equal magnitude. The cost analysis is particularly sensitive to the actual number of flexible optic intubations performed; with fewer intubations, the total cost will begin to favour disposable equipment.
© 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2012        PMID: 22338623     DOI: 10.1111/j.1399-6576.2012.02653.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  9 in total

Review 1.  Development of endotracheal intubation devices for patients with tumors.

Authors:  Yang Liu; Yang Zhang; Bin Zhu; Wenyun Xu; Yi Yang; Zui Zou
Journal:  Am J Cancer Res       Date:  2022-06-15       Impact factor: 5.942

2.  The Cost of Flexible Bronchoscopes: A Systematic Review and Meta-analysis.

Authors:  Carina Østervig Andersen; Helena Travis; Emilie Dehlholm-Lambertsen; Rasmus Russell; Emmelie Ploug Jørgensen
Journal:  Pharmacoecon Open       Date:  2022-08-22

3.  Cost analysis of single-use (Ambu® aScope™) and reusable bronchoscopes in the ICU.

Authors:  S Perbet; M Blanquet; C Mourgues; J Delmas; S Bertran; B Longère; V Boïko-Alaux; P Chennell; J-E Bazin; J-M Constantin
Journal:  Ann Intensive Care       Date:  2017-01-03       Impact factor: 6.925

4.  Early Assessment of the Likely Cost Effectiveness of Single-Use Flexible Video Bronchoscopes.

Authors:  Christoffer Lilja Terjesen; Julia Kovaleva; Lars Ehlers
Journal:  Pharmacoecon Open       Date:  2017-06

5.  A Cost-Effectiveness Analysis Comparing the VivaSight Double-Lumen Tube and a Conventional Double-Lumen Tube in Adult Patients Undergoing Thoracic Surgery Involving One-Lung Ventilation.

Authors:  Sara Larsen; Jimmy Højberg Holm; Tove Nørgaard Sauer; Claus Andersen
Journal:  Pharmacoecon Open       Date:  2020-03

6.  A systematic review and cost effectiveness analysis of reusable vs. single-use flexible bronchoscopes.

Authors:  J M Mouritsen; L Ehlers; J Kovaleva; I Ahmad; K El-Boghdadly
Journal:  Anaesthesia       Date:  2019-11-08       Impact factor: 6.955

Review 7.  Optical Devices in Tracheal Intubation-State of the Art in 2020.

Authors:  Jan Matek; Frantisek Kolek; Olga Klementova; Pavel Michalek; Tomas Vymazal
Journal:  Diagnostics (Basel)       Date:  2021-03-22

8.  Implementation of an Anaesthesia Quality Improvement Programme to Reduce Fibreoptic Bronchoscope Repair Incidents.

Authors:  Hsiao-Feng Lu; Kuo-Chuan Hung; Min-Hsien Chiang; Johnson Chia-Shen Yang; Sheng-Dean Luo; Jo-Chi Chin; Chih-Hsien Wang; Cheuk-Kwan Sun; Shao-Chun Wu
Journal:  Biomed Res Int       Date:  2020-04-12       Impact factor: 3.411

9.  Reusable vs disposable nasopharyngolaryngoscopes: Cost analysis and resident survey.

Authors:  Ryan Walczak; Mark Arnold; Jeewanjot Grewal; Xiao Yuan; Amar Suryadevara; Haidy Marzouk
Journal:  Laryngoscope Investig Otolaryngol       Date:  2020-12-10
  9 in total