Literature DB >> 2233565

Anthropomorphic radiation therapy phantoms: a quantitative assessment of tissue substitutes.

J H Kleck1, J B Smathers, F E Holly, L T Myers.   

Abstract

Compositional analyses of samples of soft tissue and lung substitutes used in the construction of anthropomorphic radiotherapy phantoms were performed for products from Alderson Research Laboratories Inc., Kyoto Scientific Specimens Company/Capintec Inc., Humanoid Systems Inc., Radiology Support Devices Inc., and The Phantom Laboratory Inc. To assess quality control in the manufacture process, the results of these compositional analyses were compared with individual manufacturer's design specifications and electron densities measured by computed tomography analysis of actual phantom slices. A comparison of the manufacturers design specifications against reference tissue parameters from Tissue Substitutes in Radiation Dosimetry and Measurement (International Commission on Radiation Units and Measurements) indicates marked differences in the basic design of commercially available anthropomorphic phantoms.

Mesh:

Year:  1990        PMID: 2233565     DOI: 10.1118/1.596552

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Characterization of a novel anthropomorphic plastinated lung phantom.

Authors:  Sungwon Yoon; Robert W Henry; Donna M Bouley; N Robert Bennett; Rebecca Fahrig
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

2.  Evaluation of the usefulness of a MOSFET detector in an anthropomorphic phantom for 6-MV photon beam.

Authors:  Ryosuke Kohno; Eriko Hirano; Satoshi Kitou; Tomonori Goka; Kana Matsubara; Satoru Kameoka; Taeko Matsuura; Takaki Ariji; Teiji Nishio; Mitsuhiko Kawashima; Takashi Ogino
Journal:  Radiol Phys Technol       Date:  2010-02-04

3.  Radiosurgery for cerebral arteriovenous malformation during pregnancy: A case report focusing on fetal exposure to radiation.

Authors:  Kazuki Nagayama; Hiroki Kurita; Ayako Tonari; Makoto Takayama; Yoshiaki Shiokawa
Journal:  Asian J Neurosurg       Date:  2010-07

4.  Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702).

Authors:  Teiji Nishio; Hiroki Shirato; Masayori Ishikawa; Yuki Miyabe; Satoshi Kito; Yuichirou Narita; Rikiya Onimaru; Satoshi Ishikura; Yoshinori Ito; Masahiro Hiraoka
Journal:  J Radiat Res       Date:  2014-01-01       Impact factor: 2.724

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.