Forward-directed bremsstrahlung of 10- to 30-MeV electrons incident on thick targets of Al and Pb.

B A Faddegon1, C K Ross, D W Rogers.   

Abstract

Bremsstrahlung spectra from thick targets of Al and Pb have been measured absolutely (photons per incident electron) along the beam axis for electrons of 10-, 15-, 20-, 25-, and 30-MeV incident energy. The spectra have a 220-keV low-energy cutoff. The targets were cylinders with nominal thicknesses of 110% of the electron CSDA range. A thin transmission detector, calibrated against a toroidal current monitor, was placed upstream of the target to measure the beam current. The spectrometer was a 20-cm diameter by 25-cm-long cylindrical NaI detector. Measured spectra were corrected for pile-up, background, detector response, detector efficiency, attenuation in materials between the target and detector and the collimator effect. Spectra were calculated using the EGS4 Monte Carlo system for simulating the radiation transport. The simulation model included the small amount of material upstream of the target. This material contributed about 40% of the spectrum, but its presence or absence had little effect on the calculated bremsstrahlung yield. The shapes of the measured and calculated spectra were in excellent agreement. The ratio of the total number of photons in each measured spectrum to those in the corresponding calculated spectrum varied from 0.97 +/- 0.06 to 1.12 +/- 0.06, depending largely on the atomic number of the target. Absolute spectral measurements in the literature agreed with our calculations of spectral shape but showed a range of +/- 30% in the number of photons per incident electron relative to the calculated values, which is contrary to our result.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2233563     DOI: 10.1118/1.596560

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Monte Carlo simulation of large electron fields.

Authors:  Bruce A Faddegon; Joseph Perl; Makoto Asai
Journal:  Phys Med Biol       Date:  2008-02-21       Impact factor: 3.609

2.  Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

Authors:  D L Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies.

Authors:  Bruce A Faddegon; Makoto Asai; Joseph Perl; Carl Ross; Josep Sempau; Jane Tinslay; Francesc Salvat
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group.

Authors:  P Arce; D Bolst; M-C Bordage; J M C Brown; P Cirrone; M A Cortés-Giraldo; D Cutajar; G Cuttone; L Desorgher; P Dondero; A Dotti; B Faddegon; C Fedon; S Guatelli; S Incerti; V Ivanchenko; D Konstantinov; I Kyriakou; G Latyshev; A Le; C Mancini-Terracciano; M Maire; A Mantero; M Novak; C Omachi; L Pandola; A Perales; Y Perrot; G Petringa; J M Quesada; J Ramos-Méndez; F Romano; A B Rosenfeld; L G Sarmiento; D Sakata; T Sasaki; I Sechopoulos; E C Simpson; T Toshito; D H Wright
Journal:  Med Phys       Date:  2020-12-12       Impact factor: 4.071

  4 in total