PURPOSE: We report on the design, performance, and specifications of a dedicated set-up for the treatment of rats on a clinical magnetic resonance high intensity focused ultrasound (MR-HIFU) system. MATERIALS AND METHODS: The small animal HIFU-compatible 4-channel MR receiver volume coil and animal support were designed as add-on to a clinical 3T Philips Sonalleve MR-HIFU system. Prolonged hyperthermia (T ≈ 42°C, 15 min) and thermal ablation (T = 65°C) was performed in vivo on subcutaneous rat tumours using 1.44 MHz acoustic frequency. The direct treatment effect was assessed with T(2)-weighted imaging and dynamic contrast enhanced (DCE-) MRI as well as histology. RESULTS: The developed HIFU-compatible coil provided an image quality that was comparable to conventional small animal volume coils (i.e. without acoustic window), and a SNR increase by a factor of 10 as compared to the coil set-up used for clinical MR-HIFU therapy. The use of an animal support minimised far field heating and allowed precise regulation of the animal body core temperature, which varied <1°C during treatment. CONCLUSIONS: The results demonstrated that, by using a designated set-up, both controlled hyperthermia and thermal ablation treatment of malignant tumours in rodents can be performed on a clinical MR-HIFU system. This approach provides all the advantages of clinical MR-HIFU, such as volumetric heating, temperature feedback control and a clinical software interface for use in rodent treatment. The use of a clinical system moreover facilitates a rapid translation of the developed protocols into the clinic.
PURPOSE: We report on the design, performance, and specifications of a dedicated set-up for the treatment of rats on a clinical magnetic resonance high intensity focused ultrasound (MR-HIFU) system. MATERIALS AND METHODS: The small animal HIFU-compatible 4-channel MR receiver volume coil and animal support were designed as add-on to a clinical 3T Philips Sonalleve MR-HIFU system. Prolonged hyperthermia (T ≈ 42°C, 15 min) and thermal ablation (T = 65°C) was performed in vivo on subcutaneous rattumours using 1.44 MHz acoustic frequency. The direct treatment effect was assessed with T(2)-weighted imaging and dynamic contrast enhanced (DCE-) MRI as well as histology. RESULTS: The developed HIFU-compatible coil provided an image quality that was comparable to conventional small animal volume coils (i.e. without acoustic window), and a SNR increase by a factor of 10 as compared to the coil set-up used for clinical MR-HIFU therapy. The use of an animal support minimised far field heating and allowed precise regulation of the animal body core temperature, which varied <1°C during treatment. CONCLUSIONS: The results demonstrated that, by using a designated set-up, both controlled hyperthermia and thermal ablation treatment of malignant tumours in rodents can be performed on a clinical MR-HIFU system. This approach provides all the advantages of clinical MR-HIFU, such as volumetric heating, temperature feedback control and a clinical software interface for use in rodent treatment. The use of a clinical system moreover facilitates a rapid translation of the developed protocols into the clinic.
Authors: Jingfei Liu; Josquin Foiret; Douglas N Stephens; Olivier Le Baron; Katherine W Ferrara Journal: Phys Med Biol Date: 2016-06-29 Impact factor: 3.609
Authors: Lifei Zhu; Michael B Altman; Andrei Laszlo; William Straube; Imran Zoberi; Dennis E Hallahan; Hong Chen Journal: Ultrasound Med Biol Date: 2019-02-14 Impact factor: 2.998
Authors: Ari Partanen; Pavel S Yarmolenko; Antti Viitala; Sunil Appanaboyina; Dieter Haemmerich; Ashish Ranjan; Genevieve Jacobs; David Woods; Julia Enholm; Bradford J Wood; Matthew R Dreher Journal: Int J Hyperthermia Date: 2012 Impact factor: 3.914
Authors: Ari Partanen; Matti Tillander; Pavel S Yarmolenko; Bradford J Wood; Matthew R Dreher; Max O Kohler Journal: Med Phys Date: 2013-01 Impact factor: 4.071
Authors: Jessie E Lee; Chris J Diederich; Robert Bok; Renuka Sriram; Romelyn Delos Santos; Susan M Noworolski; Vasant A Salgaonkar; Matthew S Adams; Daniel B Vigneron; John Kurhanewicz Journal: NMR Biomed Date: 2018-07-18 Impact factor: 4.044
Authors: H Petra Kok; Erik N K Cressman; Wim Ceelen; Christopher L Brace; Robert Ivkov; Holger Grüll; Gail Ter Haar; Peter Wust; Johannes Crezee Journal: Int J Hyperthermia Date: 2020 Impact factor: 3.914