Literature DB >> 22326135

Velocity Vector Imaging: standard tissue-tracking results acquired in normals--the VVI-STRAIN study.

Shemy Carasso1, Patric Biaggi, Harry Rakowski, Diab Mutlak, Jonathan Lessick, Doron Aronson, Anna Woo, Yoram Agmon.   

Abstract

BACKGROUND: Echocardiographic imaging assessment of left ventricular mechanics is a new technology that is offered by various vendors. Different software algorithms have at times yielded conflicting results. The aim of this study was to determine normal myocardial mechanical parameters in a healthy population using Velocity Vector Imaging.
METHODS: One hundred twenty subjects were selected for this study, including healthy subjects referred for echocardiography to evaluate minor symptoms or murmurs, who had normal echocardiographic findings and healthy volunteers. Study subjects were recruited in Haifa, Israel and Toronto, Canada. Echocardiography was performed using commercially available systems to analyze archived studies. Endocardial and epicardial longitudinal and circumferential strain and strain rate were calculated as well as rotational mechanical parameters. Age and gender differences were evaluated.
RESULTS: Average endocardial longitudinal, circumferential, and radial strains and twist were -19.6 ± 2.0%, -27.6 ± 3.9%, +30.1 ± 7.5%, and 9.6 ± 3.9°, respectively. Epicardial circumferential strain and twist were -11.3 ± 2.2% and 4.0 ± 1.9°, respectively. Shortening increased from base to apex longitudinally (10%) and circumferentially (33%). Thickening at the apex was 16% lower than at the base. Men and older subjects had increased endocardial circumferential strain and apical rotation.
CONCLUSIONS: Mechanical parameters differ with location (endocardial vs epicardial, basal vs apical strain gradients), age, and gender. Care should be taken when comparing regional strain measurements between systems, and gender and age should be matched between and within two-dimensional strain systems.
Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22326135     DOI: 10.1016/j.echo.2012.01.005

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  8 in total

1.  Worsening in Longitudinal Strain and Strain Rate Anticipates Development of Pediatric Transplant Coronary Artery Vasculopathy as Soon as One Year Following Transplant.

Authors:  Richard J Boruta; Shelley D Miyamoto; Adel K Younoszai; Sonali S Patel; Bruce F Landeck
Journal:  Pediatr Cardiol       Date:  2017-09-25       Impact factor: 1.655

2.  Left Circumflex Coronary Artery as the Culprit Vessel in ST-Segment-Elevation Myocardial Infarction.

Authors:  Diab Ghanim; Fabio Kusniec; Wadi Kinany; Dahud Qarawani; David Meerkin; Khaled Taha; Offer Amir; Shemy Carasso
Journal:  Tex Heart Inst J       Date:  2017-10-01

3.  Diminished Cardiac Performance and Left Ventricular Dimensions in Neonates with Congenital Diaphragmatic Hernia.

Authors:  Gabriel Altit; Shazia Bhombal; Krisa Van Meurs; Theresa A Tacy
Journal:  Pediatr Cardiol       Date:  2018-03-09       Impact factor: 1.655

4.  Unmasking Myocardial Dysfunction in Patients Hospitalized for Community-Acquired Pneumonia Using a 4-Chamber 3-Dimensional Volume/Strain Analysis.

Authors:  Moayad Khatib; Gabby Elbaz-Greener; Offer Amir; Shemy Carasso; Orna Nitzan; Soboh Soboh; Avi Peretz; Evgeni Hazanov; Wadia Kinany; Yusra Halahla; Liza Grosman-Rimon; Helene Houle
Journal:  J Digit Imaging       Date:  2022-06-15       Impact factor: 4.903

5.  Segmental Analysis of Cardiac Short-Axis Views Using Lagrangian Radial and Circumferential Strain.

Authors:  Chi Ma; Xiao Wang; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2015-11-16       Impact factor: 1.578

6.  Assessment of Speckle-Tracking Echocardiography-Derived Global Deformation Parameters During Supine Exercise in Children.

Authors:  Michael Y Liu; Theresa Tacy; Clifford Chin; Derek Y Obayashi; Rajesh Punn
Journal:  Pediatr Cardiol       Date:  2015-12-15       Impact factor: 1.655

7.  Ventricular strain analysis in patients with no structural heart disease using a vendor-independent speckle-tracking software.

Authors:  Hongmei Xia; Darwin F Yeung; Cristina Di Stefano; Stephen S Cha; Patricia A Pellikka; Zi Ye; Jeremy J Thaden; Hector R Villarraga
Journal:  BMC Cardiovasc Disord       Date:  2020-06-05       Impact factor: 2.298

8.  Diminished right ventricular function at diagnosis of pulmonary hypertension is associated with mortality in bronchopulmonary dysplasia.

Authors:  Gabriel Altit; Shazia Bhombal; Jeffrey Feinstein; Rachel K Hopper; Theresa A Tacy
Journal:  Pulm Circ       Date:  2019-10-14       Impact factor: 3.017

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.