Literature DB >> 223243

Cerebral cortical microfluorometry at isosbestic wavelengths for correction of vascular artifact.

R S Kramer, R D Pearlstein.   

Abstract

Microfluorometric measurements of cerebral cortical mitochondrial respiration in vivo are obscured by hemodynamic and oximetric artifacts. Isosbestic fluorometry provides appropriate correction for these vascular phenomena and permits simultaneous evaluation of mitochondrial nicotinamide adenine dinucleotide redox state, microcirculatory volume, and hemoglobin oxygenation.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 223243     DOI: 10.1126/science.223243

Source DB:  PubMed          Journal:  Science        ISSN: 0036-8075            Impact factor:   47.728


  10 in total

Review 1.  A review of attenuation correction techniques for tissue fluorescence.

Authors:  Robert S Bradley; Maureen S Thorniley
Journal:  J R Soc Interface       Date:  2006-02-22       Impact factor: 4.118

2.  Attenuation-corrected fluorescence extraction for image-guided surgery in spatial frequency domain.

Authors:  Bin Yang; Manu Sharma; James W Tunnell
Journal:  J Biomed Opt       Date:  2013-08       Impact factor: 3.170

3.  Spectral filtering modulation method for estimation of hemoglobin concentration and oxygenation based on a single fluorescence emission spectrum in tissue phantoms.

Authors:  Quan Liu; Tuan Vo-Dinh
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

4.  Imaging the awake visual cortex with a genetically encoded voltage indicator.

Authors:  Matteo Carandini; Daisuke Shimaoka; L Federico Rossi; Tatsuo K Sato; Andrea Benucci; Thomas Knöpfel
Journal:  J Neurosci       Date:  2015-01-07       Impact factor: 6.167

5.  Compact point-detection fluorescence spectroscopy system for quantifying intrinsic fluorescence redox ratio in brain cancer diagnostics.

Authors:  Quan Liu; Gerald Grant; Jianjun Li; Yan Zhang; Fangyao Hu; Shuqin Li; Christy Wilson; Kui Chen; Darell Bigner; Tuan Vo-Dinh
Journal:  J Biomed Opt       Date:  2011-03       Impact factor: 3.170

6.  Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response.

Authors:  Edward Baraghis; Anna Devor; Qianqian Fang; Vivek J Srinivasan; Weicheng Wu; Frédéric Lesage; Cenk Ayata; Karl A Kasischke; David A Boas; Sava Sakadzić
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

7.  (Semi-)quantitative analysis of reduced nicotinamide adenine dinucleotide fluorescence images of blood-perfused rat heart.

Authors:  J M Coremans; C Ince; H A Bruining; G J Puppels
Journal:  Biophys J       Date:  1997-04       Impact factor: 4.033

8.  Imaging Cortical Dynamics in GCaMP Transgenic Rats with a Head-Mounted Widefield Macroscope.

Authors:  Benjamin B Scott; Stephan Y Thiberge; Caiying Guo; D Gowanlock R Tervo; Carlos D Brody; Alla Y Karpova; David W Tank
Journal:  Neuron       Date:  2018-10-25       Impact factor: 17.173

9.  Spatial Relationship between Flavoprotein Fluorescence and the Hemodynamic Response in the Primary Visual Cortex of Alert Macaque Monkeys.

Authors:  Yevgeniy B Sirotin; Aniruddha Das
Journal:  Front Neuroenergetics       Date:  2010-06-03

10.  Global Representations of Goal-Directed Behavior in Distinct Cell Types of Mouse Neocortex.

Authors:  William E Allen; Isaac V Kauvar; Michael Z Chen; Ethan B Richman; Samuel J Yang; Ken Chan; Viviana Gradinaru; Benjamin E Deverman; Liqun Luo; Karl Deisseroth
Journal:  Neuron       Date:  2017-05-17       Impact factor: 17.173

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.