Literature DB >> 22322019

Dimensional accuracy of 2 irreversible hydrocolloid alternative impression materials with immediate and delayed pouring.

Usama Nassar1, Bayan Hussein, Andrea Oko, Jason P Carey, Carlos Flores-Mir.   

Abstract

OBJECTIVE: To assess dimensional accuracy and stability of 2 irreversible hydrocolloid alternative impression materials with immediate and delayed pouring.
METHODS: Two alternative impression materials, AlgiNot FS and Position Penta Quick, were compared with a traditional irreversible hydrocolloid, Jeltrate Plus antimicrobial alginate. Impressions were made of a metal model with 4 cylinders of known dimensions, with pouring performed immediately or after 4 hours of storage. A digital micrometer was used to measure cylinder diameter on the model and the poured casts. Dimensional changes were analyzed according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 19 (2004 version) (α=0.05).
RESULTS: There were significant differences among the 3 materials, between the 2 pour times and as a function of storage time (multivariate analysis of variance, p<0.001). One-way analysis of variance revealed no significant differences between the 2 alternative impression materials, but changes for these materials differed significantly from those for the traditional impression material for immediate (p<0.05) and 4-hour (p<0.001) pouring. Linear dimensional changes for the 2 substitute materials were within the limits of the ANSI/ADA specification.
CONCLUSIONS: With immediate pouring, both alternative impression materials exhibited minimal dimensional changes, which were maintained or reduced with 4-hour pouring. For both pouring times, these changes were less than 0.5%. CLINICAL SIGNIFICANCE: The minimal dimensional changes observed with these irreversible hydrocolloid alternative impression materials after 4 hours of storage may save chairside time and help to produce accurate results for procedures such as partial denture framework, surgical guides, and pediatric and orthodontic devices.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22322019

Source DB:  PubMed          Journal:  J Can Dent Assoc        ISSN: 0709-8936            Impact factor:   1.316


  4 in total

1.  The accuracy of gypsum casts obtained from the disinfected extended-pour alginate impressions through prolonged storage times.

Authors:  Rania A Sharif; Khalid M Abdelaziz; Najla M Alshahrani; Fatimah S Almutairi; Mohrah A Alaseri; Hoda L Abouzeid; Mohamed F A Elagib
Journal:  BMC Oral Health       Date:  2021-06-09       Impact factor: 2.757

2.  Effect of storage time of extended-pour and conventional alginate impressions on dimensional accuracy of casts.

Authors:  Ahmad Rohanian; Ghasem Ommati Shabestari; Somayeh Zeighami; Mohammad Javad Samadi; Ahmad Reza Shamshiri
Journal:  J Dent (Tehran)       Date:  2014-11-30

3.  Effect of Storage Period on Dimensional Stability of Alginplus and Hydrogum 5.

Authors:  Shima Aalaei; Rohollah Ganj-Khanloo; Fatemeh Gholami
Journal:  J Dent (Tehran)       Date:  2017-01

4.  Surface Detail Reproduction and Dimensional Stability of Contemporary Irreversible Hydrocolloid Alternatives after Immediate and Delayed Pouring.

Authors:  Preethi Kusugal; Ritu Sunil Chourasiya; Zarir Ruttonji; Preeti Astagi; Ajay Kumar Nayak; Abhishekha Patil
Journal:  Contemp Clin Dent       Date:  2018 Jan-Mar
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.