Literature DB >> 22321905

Small metal soft tissue foreign body extraction by using 3D CT guidance: a reliable method.

Kai Tao1, Sen Xu, Xiao-yan Liu, Jiu-long Liang, Tao Qiu, Jia-nan Tan, Jian-hua Che, Zi-hua Wang.   

Abstract

OBJECTIVE: To introduce a useful and accurate technique for the locating and removal of small metal foreign bodies in the soft tissues.
METHODS: Eight patients presented with suspected small metal foreign bodies retained in the soft tissues of various body districts. Under local anesthesia, 3-6 pieces of 5 ml syringe needles or 1 ml syringe needles were induced through three different planes around the entry point of the foreign bodies. Using these finders, the small metal FBs were confirmed under 3D CT guidance. Based on the CT findings, the soft tissues were dissected along the path of the closest needle and the FBs were easily found and removed according to the relation with the closest needle finder.
RESULTS: Eight metal foreign bodies (3 slices, 3 nails, 1 fish hook, 1 needlepoint) were successfully removed under 3D CT guidance in all patients. The procedures took between 35 min and 50 min and the operation times took between 15 min and 25 min. No complications arose after the treatment.
CONCLUSION: 3D CT-guided technique is a good alternative for the removal of small metal foreign body retained in the soft tissues as it is relatively accurate, reliable, quick, carries a low risk of complications and can be a first-choice procedure for the extraction of small metal foreign body.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22321905     DOI: 10.1016/j.ejrad.2012.01.002

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  3 in total

1.  Foreign body removal with the assistance of ultrasound guidance and methylene blue staining in children-a cohort study.

Authors:  Kai Chen; Menglei Wang; Yuxi Su
Journal:  Int Orthop       Date:  2022-05-10       Impact factor: 3.479

2.  Metallic foreign body deep in the prevertebral space after an endomyocardial biopsy: a case report.

Authors:  Yu-Hsuan Lin; Kuo-Ping Chang
Journal:  J Med Case Rep       Date:  2014-02-25

3.  Value of 3-dimensional CT virtual anatomy imaging in complex foreign body retrieval from soft tissues.

Authors:  Xiu-Jun Yang; Guang-Fu Xing; Chang-Wen Shi; Wei Li
Journal:  Korean J Radiol       Date:  2013-02-22       Impact factor: 3.500

  3 in total