Literature DB >> 22320780

A phantom evaluation of Sentinel(™), a commercial laser/camera surface imaging system for patient setup verification in radiotherapy.

Stefania Pallotta1, Livia Marrazzo, Marco Ceroti, Pierfrancesco Silli, Marta Bucciolini.   

Abstract

PURPOSE: The aim of this study is to investigate the performance of Sentinel(™), a patient setup verification device based on a laser/camera system, when used on rigid-body phantoms.
METHODS: The Sentinel system consists of a scanner unit, containing the laser and the camera, and surface-matching registration software. For the registration procedure, both a computed tomography (CT) and a Sentinel image can be used as a reference. Tests were performed on phantoms using an Elekta Synergy(®) beam modulator Linac equipped with a cone beam CT (CBCT), a HexaPOD RT couch top, and an iViewGT portal imaging system. Experiments conducted in this study tested reproducibility of the Sentinel surface acquisition and of set-up procedure, accuracy in quantifying known phantom mispositioning, and compared Sentinel, CBCT, and portal imaging system performance.
RESULTS: Reproducibility of surface acquisition and setup procedure was better than 0.5 mm and 0.5° and 1 mm and 0.4°, respectively. The system accuracy was better than 1 mm and 1° when a Sentinel image was used as reference. A global worsening of Sentinel performance was observed using as reference an external surface extracted from CT study. This effect is probably due to small differences in considered surfaces, caused by different imaging modalities. The results obtained by testing the system on rigid phantoms were comparable to those obtained using CBCT and better than those obtained with conventional portal imaging systems.
CONCLUSIONS: The Sentinel setup verification device is a reproducible and consistent system able to detect misalignments with accuracy better than 1 mm and 1°. When tested on rigid body phantoms, Sentinel and CBCT performed similarly. When compared to portal imaging, both Sentinel and CBCT were more accurate.

Entities:  

Mesh:

Year:  2012        PMID: 22320780     DOI: 10.1118/1.3675973

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Three-dimensional surface scanning for accurate patient positioning and monitoring during breast cancer radiotherapy.

Authors:  C Gaisberger; P Steininger; B Mitterlechner; S Huber; H Weichenberger; F Sedlmayer; H Deutschmann
Journal:  Strahlenther Onkol       Date:  2013-06-07       Impact factor: 3.621

2.  Surface imaging, portal imaging, and skin marker set-up vs. CBCT for radiotherapy of the thorax and pelvis.

Authors:  Stefania Pallotta; Eleonora Vanzi; Gabriele Simontacchi; Livia Marrazzo; Marco Ceroti; Fabiola Paiar; Lorenzo Livi; Marta Bucciolini
Journal:  Strahlenther Onkol       Date:  2015-06-19       Impact factor: 3.621

Review 3.  The impact of modern radiotherapy on long-term cardiac sequelae in breast cancer survivor: a focus on deep inspiration breath-hold (DIBH) technique.

Authors:  V Salvestrini; G C Iorio; P Borghetti; F De Felice; C Greco; V Nardone; A Fiorentino; F Gregucci; I Desideri
Journal:  J Cancer Res Clin Oncol       Date:  2021-12-01       Impact factor: 4.553

4.  A novel surface imaging system for patient positioning and surveillance during radiotherapy. A phantom study and clinical evaluation.

Authors:  F Stieler; F Wenz; M Shi; F Lohr
Journal:  Strahlenther Onkol       Date:  2013-09-27       Impact factor: 3.621

5.  Clinical evaluation of a commercial surface-imaging system for patient positioning in radiotherapy.

Authors:  F Stieler; F Wenz; D Scherrer; M Bernhardt; F Lohr
Journal:  Strahlenther Onkol       Date:  2012-11-10       Impact factor: 3.621

6.  Development of a deep inspiration breath-hold system for radiotherapy utilizing a laser distance measurer.

Authors:  Christer Andre Jensen; Nils Skottner; Jomar Frengen; Jo-Åsmund Lund
Journal:  J Appl Clin Med Phys       Date:  2016-11-24       Impact factor: 2.102

7.  AlignRT® and Catalyst™ in whole-breast radiotherapy with DIBH: Is IGRT still needed?

Authors:  Marko Laaksomaa; Sebastian Sarudis; Maija Rossi; Turkka Lehtonen; Jani Pehkonen; Jenny Remes; Helmi Luukkanen; Tanja Skyttä; Mika Kapanen
Journal:  J Appl Clin Med Phys       Date:  2019-03       Impact factor: 2.102

Review 8.  Current concepts in clinical radiation oncology.

Authors:  Michael Orth; Kirsten Lauber; Maximilian Niyazi; Anna A Friedl; Minglun Li; Cornelius Maihöfer; Lars Schüttrumpf; Anne Ernst; Olivier M Niemöller; Claus Belka
Journal:  Radiat Environ Biophys       Date:  2013-10-20       Impact factor: 1.925

Review 9.  Recent advanced in Surface Guided Radiation Therapy.

Authors:  P Freislederer; M Kügele; M Öllers; A Swinnen; T-O Sauer; C Bert; D Giantsoudi; S Corradini; V Batista
Journal:  Radiat Oncol       Date:  2020-07-31       Impact factor: 3.481

10.  Design and Construction of A Laser-Based Respiratory Gating System For Implementation of Deep Inspiration Breathe Hold Technique in Radiotherapy Clinics.

Authors:  Mohammad Javad Keikhai Farzaneh; Shahrokh Nasseri; Mehdi Momennezhad; Roham Salek
Journal:  J Med Signals Sens       Date:  2018 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.