Literature DB >> 22320391

Short implants (6 mm) installed immediately into extraction sockets: an experimental study in dogs.

Eriberto Bressan1, Stefano Sivolella, Zoraya Almagro Urrutia, Luiz Antonio Salata, Niklaus Peter Lang, Daniele Botticelli.   

Abstract

AIM: To evaluate the effect of implant length (6 mm vs.11 mm) on osseointegration (bone-to-implant contact) of implants installed into sockets immediately after tooth extraction.
MATERIAL AND METHODS: In six Labrador dogs, the pulp tissue of the mesial roots of (3) P(3) was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemi-sectioned and the distal roots removed. Recipient sites were prepared in the distal alveolus and a 6 mm or an 11 mm long implant was installed at the test and control sites, respectively. Non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment.
RESULTS: No statistically significant differences were found between test and control sites both for hard and soft tissue parameters. The bone-to-implant contact evaluated at the apical region of the implants was similar as well. Although not statistically significant, the location of the top of the bony crest at the buccal aspect was more apical in relation to the implant shoulder at the test compared with the control sites (2.0 ± 1.4 and 1.2 ± 1.1 mm, respectively).
CONCLUSIONS: Shorter implants (6 mm) present with equal osseointegration than do longer implants (11 mm).
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22320391     DOI: 10.1111/j.1600-0501.2012.02432.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

1.  Is maxillary diastema an appropriate site for implantation in rats?

Authors:  Gang Yue; Husham Edani; Andrew Sullivan; Shuying Jiang; Hamed Kazerani; Mohammad Ali Saghiri
Journal:  Int J Implant Dent       Date:  2020-02-26

2.  Evaluation of the Surrounding Ring of Two Different Extra-Short Implant Designs in Crestal Bone Maintanence: A Histologic Study in Dogs.

Authors:  José Luis Calvo-Guirado; Hilde Morales-Meléndez; Carlos Pérez-Albacete Martínez; David Morales-Schwarz; Roni Kolerman; Manuel Fernández-Domínguez; Sérgio Alexandre Gehrke; José Eduardo Maté-Sánchez de Val
Journal:  Materials (Basel)       Date:  2018-09-06       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.