Literature DB >> 22313929

The influence of different placement techniques on the microtensile bond strength of low-shrink silorane composite bonded to Class I cavities.

J S Almeida e Silva1, Juliana Nunes Rolla, Luiz Narciso Baratieri, Sylvio Monteiro.   

Abstract

The aim of this in vitro study was to evaluate the microtensile bond strength (µTBS) of a low-shrink silorane-based composite (Filtek Silorane) and a methacrylate-based composite (Filtek Z250) to the bottom dentin of a Class I cavity using different placement techniques. Twelve third molars were used. Standard, box-type Class I cavities (6.0 x 4.0 x 2.5 mm) were prepared at the occlusal crown center, with the pulpal floor ending approximately at the midcoronal dentin. The teeth were then randomly divided into four groups, according to each placement technique: ZI--Filtek Z250 placed incrementally; ZB--Filtek Z250 placed in bulk; SI--Filtek Silorane placed incrementally; and SB--Filtek Silorane placed in bulk. Each restored third molar was subjected to microtensile bond testing after 24 hours of storage in distilled water at 37 degrees C. After storage, each molar was longitudinally sectioned in both axes to obtain rectangular sticks with an approximate 0.49 mm2 cross-sectional area. Data were analyzed by one-way ANOVA followed by a Tukey post hoc test (P = 0.05). After debonding, the failure modes were analyzed using a stereomicroscope. The ZI group (72.6 MPa) showed the highest µTBS, followed by the ZB group (60.2 MPa), while the SI (34.4 MPa) and SB (42.6 MPa) groups demonstrated statistically significant lower bond strengths. The type of placement technique did not influence the µTBS of silorane-based composites to the bottom dentin of Class I cavities. The methacrylate-based composite showed superior performance, regardless of the placement technique.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22313929

Source DB:  PubMed          Journal:  Gen Dent        ISSN: 0363-6771


  3 in total

Review 1.  Low-Shrinkage Resin Matrices in Restorative Dentistry-Narrative Review.

Authors:  Ebtehal G Albeshir; Rashed Alsahafi; Reem Albluwi; Abdulrahman A Balhaddad; Heba Mitwalli; Thomas W Oates; Gary D Hack; Jirun Sun; Michael D Weir; Hockin H K Xu
Journal:  Materials (Basel)       Date:  2022-04-18       Impact factor: 3.748

2.  Evaluation of bond strength of silorane and methacrylate based restorative systems to dentin using different cavity models.

Authors:  Stephano Zerlottini Isaac; Ana Claudia Pietrobom Bergamin; Cecília Pedroso Turssi; Flávia Lucisano Botelho do Amaral; Roberta Tarkany Basting; Fabiana Mantovani Gomes França
Journal:  J Appl Oral Sci       Date:  2013 Sep-Oct       Impact factor: 2.698

3.  Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth.

Authors:  Sharifi M; Khoramian Tusi S
Journal:  J Dent Biomater       Date:  2016-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.