Literature DB >> 22313314

Comparison between atrial fibrillation-triggered implantable cardioverter-defibrillator (ICD) shocks and inappropriate shocks caused by lead failure: different impact on prognosis in clinical practice.

Thomas Kleemann1, Matthias Hochadel, Margit Strauss, Alexandros Skarlos, Karlheinz Seidl, Ralf Zahn.   

Abstract

INTRODUCTION: Recent studies suggest a worse impact of inappropriate shock therapies on the outcome of patients with an implantable cardioverter-defibrillator (ICD). However, it is not known whether the worse impact is attributed to the ICD shock itself or due to the underlying heart disease. The aim of the study was to evaluate the impact of inappropriate ICD shocks on clinical outcome by comparing ICD shocks triggered by atrial fibrillation (AF) with shocks caused by lead failure. METHODS AND
RESULTS: A total of 1,411 consecutive patients of the prospective single-center ICD-registry Ludwigshafen who underwent an ICD implantation between 1992 and 2008 for primary or secondary prevention of sudden cardiac death were analyzed. During the median follow-up of 3 years, 297 (21%) patients experienced inappropriate ICD shocks. Sixty percent of patients had inappropriate shocks due to AF and 24% due to lead defect or T-wave oversensing. Multiple ICD shocks (≥2) triggered by AF were associated with a worse prognosis, whereas a single shock due to AF or 1 or multiple shocks resulting from lead failure were not. ICD shocks caused by AF occurred more often in tandem with a serious adverse event than in patients with a lead failure (15% vs 6%, P < 0.05).
CONCLUSION: Multiple ICD shocks triggered by AF are associated with a worse prognosis in ICD patients, whereas a single shock due to AF or shocks resulting from lead failure are not. These data support that the ICD shock itself has no worse impact on the outcome of ICD patients.
© 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22313314     DOI: 10.1111/j.1540-8167.2011.02279.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  15 in total

Review 1.  [What must intensive care physicians know about implantable cardioverter defibrillator?].

Authors:  E Gatterer
Journal:  Med Klin Intensivmed Notfmed       Date:  2013-09-20       Impact factor: 0.840

2.  The Significance of Shocks in Implantable Cardioverter Defibrillator Recipients.

Authors:  Anthony Li; Amit Kaura; Nicholas Sunderland; Paramdeep S Dhillon; Paul A Scott
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-08

3.  [Inappropriate ICD therapies: All problems solved with MADIT-RIT?].

Authors:  Christof Kolb
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-04-21

Review 4.  Management of Patients with Atrial Fibrillation: Focus on Treatment Options.

Authors:  Pawel Matusik; Jacek Lelakowski; Barbara Malecka; Jacek Bednarek; Remigiusz Noworolski
Journal:  J Atr Fibrillation       Date:  2016-10-31

Review 5.  [Patients with implanted devices in intensive care medicine].

Authors:  K M Heinroth
Journal:  Med Klin Intensivmed Notfmed       Date:  2012-05-04       Impact factor: 0.840

6.  Prognostic relevance of new onset arrhythmia and ICD shocks in primary prophylactic ICD patients.

Authors:  Thomas Kleemann; Margit Strauss; Kleopatra Kouraki; Nicolas Werner; Ralf Zahn
Journal:  Clin Res Cardiol       Date:  2019-05-13       Impact factor: 5.460

Review 7.  Atrial fibrillation is associated with sudden cardiac death: a systematic review and meta-analysis.

Authors:  Pattara Rattanawong; Sikarin Upala; Tanawan Riangwiwat; Veeravich Jaruvongvanich; Anawin Sanguankeo; Wasawat Vutthikraivit; Eugene H Chung
Journal:  J Interv Card Electrophysiol       Date:  2018-01-13       Impact factor: 1.900

Review 8.  Adverse events following implantable cardioverter defibrillator implantation: a systematic review.

Authors:  Rebecca Persson; Amy Earley; Ann C Garlitski; Ethan M Balk; Katrin Uhlig
Journal:  J Interv Card Electrophysiol       Date:  2014-06-20       Impact factor: 1.900

9.  Risk Stratification in Atrial Fibrillation Patients - A Review Focused on Mortality.

Authors:  Federico Lombardi
Journal:  Arrhythm Electrophysiol Rev       Date:  2012-09

10.  First time description of early lead failure of the Linox Smart lead compared to other contemporary high-voltage leads.

Authors:  Vanessa Weberndörfer; Tobias Nyffenegger; Ian Russi; Miriam Brinkert; Benjamin Berte; Stefan Toggweiler; Richard Kobza
Journal:  J Interv Card Electrophysiol       Date:  2018-05-01       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.