Literature DB >> 22310397

Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician.

Falk Mittag1, Ingmar Ipach, Ralf Schaefer, Christoph Meisner, Ulf Leichtle.   

Abstract

Digital preoperative templating is increasingly used to predict the correct component size in total hip arthroplasty (THA). Experienced surgeons could avoid the new technique and rely on a digital template done by a younger colleague. We compared the accuracy of preoperative templating between orthopedic residents (group A) and an experienced orthopedic surgeon (group B). In 106 cases, the software-predicted component sizes of both groups were compared with component sizes placed surgically. An accurate prediction of the acetabular component was achieved in 63% of cases in group A compared with 88% of cases in group B (P=.001). Concerning the femoral component, accurate prediction was achieved in 89% in group A and 97% in group B (P=.021). If performed by an experienced orthopedic surgeon, digital templating is an accurate method to predict the prosthetic component size in THA. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22310397     DOI: 10.3928/01477447-20120123-14

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

1.  Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty.

Authors:  Mina Derias; Muhammad A Khan; Jamie Buchanan
Journal:  Eur J Trauma Emerg Surg       Date:  2018-09-12       Impact factor: 3.693

2.  The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty.

Authors:  Florian Schmidutz; Arnd Steinbrück; Lorenz Wanke-Jellinek; Matthias Pietschmann; Volkmar Jansson; Andreas Fottner
Journal:  Int Orthop       Date:  2012-04-04       Impact factor: 3.075

3.  The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty.

Authors:  R Kearney; A H Shaikh; J M O'Byrne
Journal:  Ir J Med Sci       Date:  2013-01-25       Impact factor: 1.568

Review 4.  The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis.

Authors:  Joshua B V Smith; Habeeb Bishi; Chao Wang; Vipin Asopa; Richard E Field; David H Sochart
Journal:  EFORT Open Rev       Date:  2021-11-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.