Acoustic wave based MEMS devices for biosensing applications.

Ioana Voiculescu1, Anis Nurashikin Nordin.   

Abstract

This paper presents a review of acoustic-wave based MEMS devices that offer a promising technology platform for the development of sensitive, portable, real-time biosensors. MEMS fabrication of acoustic wave based biosensors enables device miniaturization, power consumption reduction and integration with electronic circuits. For biological applications, the biosensors are integrated in a microfluidic system and the sensing area is coated with a biospecific layer. When a bioanalyte interacts with the sensing layer, mass and viscosity variations of the biospecific layer can be detected by monitoring changes in the acoustic wave properties such as velocity, attenuation, resonant frequency and delay time. Few types of acoustic wave devices could be integrated in microfluidic systems without significant degradation of the quality factor. The acoustic wave based MEMS devices reported in the literature as biosensors and presented in this review are film bulk acoustic wave resonators (FBAR), surface acoustic waves (SAW) resonators and SAW delay lines. Different approaches to the realization of FBARs, SAW resonators and SAW delay lines for various biochemical applications are presented. Methods of integration of the acoustic wave MEMS devices in the microfluidic systems and functionalization strategies will be also discussed.
Copyright © 2011 Elsevier B.V. All rights reserved.

Mesh:

Year:  2012        PMID: 22310157     DOI: 10.1016/j.bios.2011.12.041

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  25 in total

1.  Rapid detection of human immunodeficiency virus types 1 and 2 by use of an improved piezoelectric biosensor.

Authors:  Marco Bisoffi; Virginia Severns; Darren W Branch; Thayne L Edwards; Richard S Larson
Journal:  J Clin Microbiol       Date:  2013-03-20       Impact factor: 5.948

2.  All-nanofiber-based, ultrasensitive, gas-permeable mechanoacoustic sensors for continuous long-term heart monitoring.

Authors:  Md Osman Goni Nayeem; Sunghoon Lee; Hanbit Jin; Naoji Matsuhisa; Hiroaki Jinno; Akihito Miyamoto; Tomoyuki Yokota; Takao Someya
Journal:  Proc Natl Acad Sci U S A       Date:  2020-03-18       Impact factor: 11.205

3.  Analyte capture in an array of functionalized droplets for a regenerable biosensor.

Authors:  C-L Azzopardi; F Chollet; J-F Manceau; W Boireau
Journal:  Biomicrofluidics       Date:  2019-09-30       Impact factor: 2.800

4.  Additive manufacturing of three-dimensional (3D) microfluidic-based microelectromechanical systems (MEMS) for acoustofluidic applications.

Authors:  Ellen Cesewski; Alexander P Haring; Yuxin Tong; Manjot Singh; Rajan Thakur; Sahil Laheri; Kaitlin A Read; Michael D Powell; Kenneth J Oestreich; Blake N Johnson
Journal:  Lab Chip       Date:  2018-07-10       Impact factor: 6.799

5.  Detection of Extremely Low Concentrations of Biological Substances Using Near-Field Illumination.

Authors:  Masato Yasuura; Makoto Fujimaki
Journal:  Sci Rep       Date:  2016-12-19       Impact factor: 4.379

6.  Single Interdigital Transducer Approach for Gravimetrical SAW Sensor Applications in Liquid Environments.

Authors:  Vu Hoa Nguyen; Corinna Kaulen; Ulrich Simon; Uwe Schnakenberg
Journal:  Sensors (Basel)       Date:  2017-12-17       Impact factor: 3.576

7.  Regenerable ZnO/GaAs Bulk Acoustic Wave Biosensor for Detection of Escherichia coli in "Complex" Biological Medium.

Authors:  Juliana Chawich; Walid M Hassen; Céline Elie-Caille; Thérèse Leblois; Jan J Dubowski
Journal:  Biosensors (Basel)       Date:  2021-05-07

8.  A multi-parameter decoupling method with a Lamb wave sensor for improving the selectivity of label-free liquid detection.

Authors:  Lianqun Zhou; Yihui Wu; Ming Xuan; Jean-François Manceau; François Bastien
Journal:  Sensors (Basel)       Date:  2012-07-31       Impact factor: 3.576

9.  A novel cell-based hybrid acoustic wave biosensor with impedimetric sensing capabilities.

Authors:  Fei Liu; Fang Li; Anis Nurashikin Nordin; Ioana Voiculescu
Journal:  Sensors (Basel)       Date:  2013-03-04       Impact factor: 3.576

10.  Streptavidin Modified ZnO Film Bulk Acoustic Resonator for Detection of Tumor Marker Mucin 1.

Authors:  Dan Zheng; Peng Guo; Juan Xiong; Shengfu Wang
Journal:  Nanoscale Res Lett       Date:  2016-09-13       Impact factor: 4.703

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.