| Literature DB >> 2231006 |
G Sgouros1, G Barest, J Thekkumthala, C Chui, R Mohan, R E Bigler, P B Zanzonico.
Abstract
A calculational approach is described that provides the spatially varying radiation absorbed dose, presented as isodose contours superimposed on CT images, from nonuniform and/or irregular cumulated activity distributions. CT images are read from magnetic tape and are displayed on a high-resolution color graphics display monitor. Source tissue geometries are defined on a series of contiguous CT images automatically (by an edge detection algorithm) or manually (using a trackball), thereby obtaining a three-dimensional representation of the various source volumes of activity. Dose calculations are performed using a radionuclide-specific absorbed dose point kernel in the form of a lookup table. The method described yields the spatially varying dose delivered to tumor and normal tissue volumes from a patient-specific cumulated activity distribution in a clinically implementable manner. This level of accuracy in determining normal tissue and tumor doses may prove valuable in the evaluation and implementation of radionuclides and radiolabeled compounds for therapeutic purposes.Entities:
Mesh:
Year: 1990 PMID: 2231006
Source DB: PubMed Journal: J Nucl Med ISSN: 0161-5505 Impact factor: 10.057