Literature DB >> 2230859

Recognition accuracy with a voice-recognition system designed for anesthesia record keeping.

N T Smith1, R A Brien, D C Pettus, B R Jones, M L Quinn, A Sarnat.   

Abstract

We tested on three occasions, with anesthetists as subjects, the accuracy of two voice-recognition systems designed for anesthetic record keeping. Initially, a prototype system was tested (10 subjects); several years later the resulting commercial system was tested in a quiet environment (11 subjects) and in noisy operating rooms (10 subjects). For each test an anesthetist first trained the system to recognize his or her voice by reading aloud a list of common anesthetic terms. To determine recognition accuracy, the percentage of words recognized correctly by the computer, each subject repeated the vocabulary words ten times. Although accuracy was similar during the three tests, it was slightly higher with the laboratory test (mean percent of words recognized correctly, 96.5%; range of accuracy for individual anesthetists, 91.6 to 98.8%) than with the prototype test (95.9%; range, 89.1 to 99.6%). Accuracy was lowest with the operating room test (95.3%; range, 87.8 to 98.4%). Twenty-four words caused particular difficulty during the laboratory test and were eliminated from the vocabulary of the subsequent operating room test. Omitting these 24 words from the laboratory vocabulary list allowed a more nearly direct comparison with the results from the operating room list; recognition accuracy improved in the former to 97.5% (range, 92.1 to 98.9%). Two anesthetists--one each from the laboratory and operating room tests--performed poorly, and eliminating their scores changed the respective overall scores to 98.2% (range, 96.7 to 98.9%) and 96.5% (range, 94.3 to 98.4%). Thus, the corrected difference between the laboratory accuracy and the operating room accuracy was 1.7%.(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Year:  1990        PMID: 2230859     DOI: 10.1007/bf02842489

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  1 in total

1.  Noise in the operating room.

Authors:  R A Shapiro; T Berland
Journal:  N Engl J Med       Date:  1972-12-14       Impact factor: 91.245

  1 in total
  8 in total

1.  Acceptance of a speech interface for biomedical data collection.

Authors:  M A Grasso; D Ebert; T Finin
Journal:  Proc AMIA Annu Fall Symp       Date:  1997

Review 2.  Patient data management systems in anaesthesia: an emerging technology.

Authors:  Y G Weiss; S Cotev; B Drenger; R Katzenelson
Journal:  Can J Anaesth       Date:  1995-10       Impact factor: 5.063

3.  A case study in designing speech interaction with a patient monitor.

Authors:  A Jungk; B Thull; L Fehrle; A Hoeft; G Rau
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

4.  Ergonomic automated anesthesia recordkeeper using a mobile touch screen with voice navigtion.

Authors:  Y Sanjo; T Yokoyama; S Sato; K Ikeda; R Nakajima
Journal:  J Clin Monit Comput       Date:  1999-08       Impact factor: 2.502

Review 5.  Risks and benefits of speech recognition for clinical documentation: a systematic review.

Authors:  Tobias Hodgson; Enrico Coiera
Journal:  J Am Med Inform Assoc       Date:  2015-11-17       Impact factor: 4.497

6.  Measurement of user performance and attitudes assists the initial design of a computer user display and orientation method.

Authors:  C R Chase; T Ashikaga; J E Mazuzan
Journal:  J Clin Monit       Date:  1994-07

7.  Development of a computerized database for the study of anaesthesia care.

Authors:  D K Rose; M M Cohen; D F Wigglesworth; D A Yee
Journal:  Can J Anaesth       Date:  1992-09       Impact factor: 5.063

8.  Analysis of Errors in Dictated Clinical Documents Assisted by Speech Recognition Software and Professional Transcriptionists.

Authors:  Li Zhou; Suzanne V Blackley; Leigh Kowalski; Raymond Doan; Warren W Acker; Adam B Landman; Evgeni Kontrient; David Mack; Marie Meteer; David W Bates; Foster R Goss
Journal:  JAMA Netw Open       Date:  2018-07-06
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.