Validation of the BacT/ALERT(R) 3D System for Rapid Sterility Testing of Biopharmaceutical Samples.

Luis Jimenez1, Narendra Rana, Joseph Amalraj, Kimberly Walker, Kasey Travers.   

Abstract

The BacT/ALERT® 3D system was validated to determine the sterility of different types of biopharmaceutical samples such as water for injection, unprocessed bulk, and finished bulk. The installation, operation, and performance qualification were completed and verified under good manufacturing practices. During the installation and operation validation stages, the functionality and security of the system and software were completed and verified. For the performance qualification, 11 microorganisms were evaluated, six compendial (Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus subtilis, Candida albicans, Aspergillus niger, Clostridium sporogenes), one representing the number one microbial species in sterile product recalls (Burkholderia cepacia), and four environmental isolates (Kocuria rhizophila, Staphylococcus haemolyticus, Methylobacterium radiotolerans, and Penicillium spp.). Nine of the microorganisms were spiked into three different types of biopharmaceutical samples by three different analysts on different days to ascertain the equivalence, ruggedness, sensitivity, time of detection, and repeatability. In all samples, the BacT/ALERT® exhibited equivalent or better detection than the standard test. With the exception of M. radiotolerans, all 11 microorganisms were detected within 2.5 days using the BacT/ALERT® system and the standard test. The detection times for M. radiotolerans in the three sample types averaged 5.77 days. The minimum detectable level of cells for all the microorganisms tested was found to be within 1 to 2 CFU. The system optimized sterility testing by the simultaneous on-line, non-destructive incubation and detection of microbial growth.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22307661     DOI: 10.5731/pdajpst.2012.00790

Source DB:  PubMed          Journal:  PDA J Pharm Sci Technol        ISSN: 1079-7440


  4 in total

1.  [Validation of an automatic test system for sterile testing of amniotic membranes].

Authors:  H Thomasen; K-P Steuhl; D Meller
Journal:  Ophthalmologe       Date:  2014-05       Impact factor: 1.059

2.  Microbiological Control of Cellular Products: The Relevance of the Cellular Matrix, Incubation Temperature, and Atmosphere for the Detection Performance of Automated Culture Systems.

Authors:  Susanne-Katharina Günther; Celina Geiss; Stefan J Kaiser; Nico T Mutters; Frank Günther
Journal:  Transfus Med Hemother       Date:  2019-10-22       Impact factor: 3.747

3.  Standardized GMP-compliant scalable production of human pancreas organoids.

Authors:  Marta Dossena; Roberta Piras; Alessandro Cherubini; Mario Barilani; Erica Dugnani; Francesca Salanitro; Till Moreth; Francesco Pampaloni; Lorenzo Piemonti; Lorenza Lazzari
Journal:  Stem Cell Res Ther       Date:  2020-03-04       Impact factor: 6.832

4.  Tips and Tricks for Validation of Quality Control Analytical Methods in Good Manufacturing Practice Mesenchymal Stromal Cell Production.

Authors:  Mariele Viganò; Silvia Budelli; Cristiana Lavazza; Tiziana Montemurro; Elisa Montelatici; Stefania de Cesare; Lorenza Lazzari; Anna Rosa Orlandi; Giovanna Lunghi; Rosaria Giordano
Journal:  Stem Cells Int       Date:  2018-09-04       Impact factor: 5.443

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.