Literature DB >> 22306442

Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems.

T Y Fu1, P Gent, V Kumar.   

Abstract

BACKGROUND: This was a head-to-head comparison of two hydrogen-peroxide-based room decontamination systems. AIM: To compare the efficacy, efficiency and safety of hydrogen peroxide vapour (HPV; Clarus R, Bioquell, Andover, U.K.) and aerosolized hydrogen peroxide (aHP; SR2, Sterinis, now supplied as Glosair, Advanced Sterilization Products (ASP), Johnson & Johnson Medical Ltd, Wokingham, U.K.) room disinfection systems.
METHOD: Efficacy was tested using 4- and 6-log Geobacillus stearothermophilus biological indicators (BIs) and in-house prepared test discs containing approximately 10(6) meticillin-resistant Staphylococcus aureus (MRSA), Clostridium difficile and Acinetobacter baumannii. Safety was assessed by detecting leakage of hydrogen peroxide using a hand-held detector. Efficiency was assessed by measuring the level of hydrogen peroxide using a hand-held sensor at three locations inside the room, 2 h after the start of the cycles.
FINDINGS: HPV generally achieved a 6-log reduction, whereas aHP generally achieved less than a 4-log reduction on the BIs and in-house prepared test discs. Uneven distribution was evident for the aHP system but not the HPV system. Hydrogen peroxide leakage during aHP cycles with the door unsealed, as per the manufacturer's operating manual, exceeded the short-term exposure limit (2 ppm) for more than 2 h. When the door was sealed with tape, as per the HPV system, hydrogen peroxide leakage was <1 ppm for both systems. The mean concentration of hydrogen peroxide in the room 2 h after the cycle started was 1.3 [standard deviation (SD) 0.4] ppm and 2.8 (SD 0.8) ppm for the four HPV and aHP cycles, respectively. None of the readings were <2 ppm for the aHP cycles.
CONCLUSION: The HPV system was safer, faster and more effective for biological inactivation. Crown Copyright Â
© 2012. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22306442     DOI: 10.1016/j.jhin.2011.11.019

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  28 in total

1.  Managing transmission of carbapenem-resistant enterobacteriaceae in healthcare settings: a view from the trenches.

Authors:  Tara N Palmore; David K Henderson
Journal:  Clin Infect Dis       Date:  2013-08-09       Impact factor: 9.079

Review 2.  The role of the healthcare environment in the spread of multidrug-resistant organisms: update on current best practices for containment.

Authors:  Roy F Chemaly; Sarah Simmons; Charles Dale; Shashank S Ghantoji; Maria Rodriguez; Julie Gubb; Julie Stachowiak; Mark Stibich
Journal:  Ther Adv Infect Dis       Date:  2014-06

3.  epic3: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England.

Authors:  H P Loveday; J A Wilson; R J Pratt; M Golsorkhi; A Tingle; A Bak; J Browne; J Prieto; M Wilcox
Journal:  J Hosp Infect       Date:  2014-01       Impact factor: 3.926

4.  Improvement of Vivarium Biodecontamination through Data-acquisition Systems and Automation.

Authors:  Shakthi Rk Devan; Suresh Vasu; Yogesha Mallikarjuna; Ramkumar Ponraj; Gireesh Kamath; Suresh Poosala
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-03-01       Impact factor: 1.232

5.  Ultraviolet-C and other methods of decontamination of filtering facepiece N-95 respirators during the COVID-19 pandemic.

Authors:  Angeli Eloise Torres; Alexis B Lyons; Shanthi Narla; Indermeet Kohli; Angela Parks-Miller; David Ozog; Iltefat H Hamzavi; Henry W Lim
Journal:  Photochem Photobiol Sci       Date:  2020-05-15       Impact factor: 3.982

6.  Examination of Material Compatibilities with Ionized and Vaporized Hydrogen Peroxide Decontamination.

Authors:  Tohru Kimura; Hiroyuki Yahata; Yoshimichi Uchiyama
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-09-17       Impact factor: 1.232

7.  Evaluation of Peroxides and Chlorine Oxides as Disinfectants for Chemical Sterilization of Gnotobiotic Rodent Isolators.

Authors:  LaTisha V Moody; Yukiko Miyamoto; Jonathan Ang; Philip J Richter; Lars Eckmann
Journal:  J Am Assoc Lab Anim Sci       Date:  2019-07-18       Impact factor: 1.232

8.  Comparative antimicrobial activities of aerosolized sodium hypochlorite, chlorine dioxide, and electrochemically activated solutions evaluated using a novel standardized assay.

Authors:  R M S Thorn; G M Robinson; D M Reynolds
Journal:  Antimicrob Agents Chemother       Date:  2013-03-04       Impact factor: 5.191

9.  Touchless Technologies for Decontamination in the Hospital: a Review of Hydrogen Peroxide and UV Devices.

Authors:  Michelle Doll; Daniel J Morgan; Deverick Anderson; Gonzalo Bearman
Journal:  Curr Infect Dis Rep       Date:  2015-09       Impact factor: 3.725

10.  Virucidal Efficacy of a Hydrogen Peroxide Nebulization Against Murine Norovirus and Feline Calicivirus, Two Surrogates of Human Norovirus.

Authors:  William Zonta; Axel Mauroy; Frederic Farnir; Etienne Thiry
Journal:  Food Environ Virol       Date:  2016-07-06       Impact factor: 2.778

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.