Literature DB >> 22305437

Evaluation of spontaneous third ventriculostomy by three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence by 3T MR imaging: preliminary results with variant flip-angle mode.

Oktay Algin1, Baris Turkbey, Evrim Ozmen, Gokhan Ocakoglu, Mustafa Karaoglanoglu, Halil Arslan.   

Abstract

PURPOSE: This prospective study aimed to evaluate the use of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) in the diagnosis of spontaneous third ventriculostomy (STV) and to compare it with phase-contrast cine magnetic resonance imaging (PC-MRI).
METHODS: PC-MRI and 3D-SPACE images were obtained in 15 patients with hydrocephalus for evaluation of STV as well as in 10 control cases. The presence of STV was evaluated visually by two experienced radiologists on both PC-MRI and 3D-SPACE images, and the results were statistically compared.
RESULTS: There was a strong correlation between PC-MRI and SPACE scores for both readers (correlation coefficient [r]=0.784; P=0.001). There was also a good correlation between PC-MRI scores and consensus-based results. Interobserver reliabilities were strong for all STV scores. In addition, there was excellent correlation between 3D-SPACE scores and consensus-based results (first reader's kappa value: 0.87; second reader's kappa value: 1).
CONCLUSION: 3D-SPACE can provide morphological-physiological information for the evaluation of STV with no need for additional PC-MRI analysis or other sequences. As a non-invasive test, it can also be included among the first line of choices of MRI sequences for patients with obstructive hydrocephalus.
Copyright © 2011 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22305437     DOI: 10.1016/j.neurad.2011.12.003

Source DB:  PubMed          Journal:  J Neuroradiol        ISSN: 0150-9861            Impact factor:   3.447


  7 in total

Review 1.  Spontaneous third ventriculostomy 8 years after diagnosis of obstructive hydrocephalus.

Authors:  Ahmet Öğrenci; Murat Şakir Ekşi; Orkun Koban
Journal:  Childs Nerv Syst       Date:  2016-04-23       Impact factor: 1.475

2.  Prediction of endoscopic third ventriculostomy (ETV) success with 3D-SPACE technique.

Authors:  Oktay Algin
Journal:  Neurosurg Rev       Date:  2014-12-17       Impact factor: 3.042

3.  Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences.

Authors:  Murat Ucar; Nil Tokgoz; Cagri Damar; Ayse Gul Alimli; Fatih Oncu
Journal:  Jpn J Radiol       Date:  2015-01-07       Impact factor: 2.374

4.  Assessment of pituitary micro-lesions using 3D sampling perfection with application-optimized contrasts using different flip-angle evolutions.

Authors:  Jing Wang; Yue Wu; Zhenwei Yao; Zhong Yang
Journal:  Neuroradiology       Date:  2014-09-24       Impact factor: 2.804

5.  Evaluation of aqueductal patency in patients with hydrocephalus: three-dimensional high-sampling-efficiency technique (SPACE) versus two-dimensional turbo spin echo at 3 Tesla.

Authors:  Murat Ucar; Melike Guryildirim; Nil Tokgoz; Koray Kilic; Alp Borcek; Yusuf Oner; Koray Akkan; Turgut Tali
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

6.  Evaluation of hydrocephalus and other cerebrospinal fluid disorders with MRI: An update.

Authors:  Merve Gulbiz Kartal; Oktay Algin
Journal:  Insights Imaging       Date:  2014-06-06

7.  Case report: Flattening of the tectal plate in obstructive hydrocephalus with auto-ventriculostomy.

Authors:  Michael Städt; Markus Holtmannspötter; Johannes Schwab; Florian Eff; Heinz Voit-Höhne
Journal:  Neuroradiol J       Date:  2021-08-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.