UNLABELLED: The present study assessed the diagnostic performances of 18F-FDG PET or PET/CT in detecting pelvic and/or paraaortic lymph node metastasis in patients with endometrial cancer. METHODS: Through a search of MEDLINE (January 1998 to March 2011), an overall weighted average for sensitivity and specificity as well as pooled estimates of positive and negative likelihood ratios were calculated. A summary receiver-operating-characteristics (sROC) curve was constructed and the area under the sROC curve (AUC) was calculated. I-square was calculated to explore heterogeneity. RESULTS: The present study included 243 patients from seven studies. Results indicated a lack of significant heterogeneity for sensitivity and specificity (I2<50% and p>0.05). The overall pooled estimates for sensitivity and specificity of FDG-PET or PET/CT scans in the detection of pelvic and/or paraaortic metastasis were 63.0% (95% CI, 48.7-75.7%) and 94.7% (95% CI, 90.4-97.4%), respectively. The positive likelihood ratio was 10.465 (95% CI, 5.646-19.396) and the negative likelihood ratio 0.399 (95% CI, 0.284-0.560). The AUC was 0.9533. The overall diagnostic accuracy (Q* index) was 89.5%. Conclusion The high positive likelihood value confirms the reliability of a positive FDG-PET or PET/CT to detect pelvic and/or paraaortic lymph nodes metastasis in patients with untreated endometrial cancer. FDG-PET or PET/CT may prove beneficial to surgeons when selecting appropriate patients on whom to perform lymphadenectomy.
UNLABELLED: The present study assessed the diagnostic performances of 18F-FDG PET or PET/CT in detecting pelvic and/or paraaortic lymph node metastasis in patients with endometrial cancer. METHODS: Through a search of MEDLINE (January 1998 to March 2011), an overall weighted average for sensitivity and specificity as well as pooled estimates of positive and negative likelihood ratios were calculated. A summary receiver-operating-characteristics (sROC) curve was constructed and the area under the sROC curve (AUC) was calculated. I-square was calculated to explore heterogeneity. RESULTS: The present study included 243 patients from seven studies. Results indicated a lack of significant heterogeneity for sensitivity and specificity (I2<50% and p>0.05). The overall pooled estimates for sensitivity and specificity of FDG-PET or PET/CT scans in the detection of pelvic and/or paraaortic metastasis were 63.0% (95% CI, 48.7-75.7%) and 94.7% (95% CI, 90.4-97.4%), respectively. The positive likelihood ratio was 10.465 (95% CI, 5.646-19.396) and the negative likelihood ratio 0.399 (95% CI, 0.284-0.560). The AUC was 0.9533. The overall diagnostic accuracy (Q* index) was 89.5%. Conclusion The high positive likelihood value confirms the reliability of a positive FDG-PET or PET/CT to detect pelvic and/or paraaortic lymph nodes metastasis in patients with untreated endometrial cancer. FDG-PET or PET/CT may prove beneficial to surgeons when selecting appropriate patients on whom to perform lymphadenectomy.
Authors: Nikhil G Thaker; Ann H Klopp; Anuja Jhingran; Michael Frumovitz; Revathy B Iyer; Patricia J Eifel Journal: Gynecol Oncol Date: 2014-12-16 Impact factor: 5.482
Authors: Mostafa Atri; Zheng Zhang; Farrokh Dehdashti; Susanna I Lee; Helga Marques; Shamshad Ali; Wui-Jin Koh; Robert S Mannel; Paul DiSilvestro; Stephanie A King; Michael Pearl; XunClare Zhou; Marie Plante; Katherine M Moxley; Michael Gold Journal: Radiology Date: 2017-01-03 Impact factor: 11.105