Literature DB >> 22302446

Biomechanical testing of fracture fixation constructs: variability, validity, and clinical applicability.

Michael J Gardner1, Matthew J Silva, James C Krieg.   

Abstract

Biomechanical testing of fracture fixation implants is crucial in preclinical evaluation and in comparing new devices with standard devices. Many variables must be considered when planning and implementing a biomechanical in vitro experiment. The type of test selected (eg, load-to-failure, stiffness, cyclic fatigue) depends on the research question being asked. For example, cyclic fatigue testing attempts to replicate clinical situations; thus, the load magnitudes and directions and the number of cycles should be decided accordingly. Most important, each bone and region of bone experiences specific in vivo forces based on muscular and other forces. Debate persists regarding whether cadaver or synthetic bone is optimal. The use of either material in biomechanical testing should be carefully considered and justified in the context of the study hypothesis. Appropriate study design is the main factor that affects the clinical applicability of the findings and the accuracy of the conclusions.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22302446     DOI: 10.5435/JAAOS-20-02-086

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   4.000


  10 in total

1.  Locking buttons increase fatigue life of locking plates in a segmental bone defect model.

Authors:  Marc Tompkins; David J Paller; Douglas C Moore; Joseph J Crisco; Richard M Terek
Journal:  Clin Orthop Relat Res       Date:  2012-10-27       Impact factor: 4.176

2.  Single or Double Plating for Acromial Type III Fractures: Biomechanical Comparison of Load to Failure and Fragment Motion.

Authors:  Marianne Hollensteiner; Sabrina Sandriesser; Felix Rittenschober; Josef Hochreiter; Peter Augat; Lukas Ernstbrunner; Reinhold Ortmaier
Journal:  J Clin Med       Date:  2022-05-31       Impact factor: 4.964

3.  Mechanical comparison of iliosacral reconstruction techniques after sarcoma resection.

Authors:  Craig R Louer; Nader A Nassif; Michael D Brodt; Daniel J Leib; Matthew J Silva; Douglas J McDonald
Journal:  Clin Biomech (Bristol, Avon)       Date:  2016-08-17       Impact factor: 2.063

4.  Double-bundle posterior cruciate ligament reconstruction: a biomechanical analysis of simulated early motion and partial and full weightbearing on common reconstruction grafts.

Authors:  William R Mook; David Civitarese; Travis Lee Turnbull; Nicholas I Kennedy; Luke O'Brien; Jarod B Schoeberl; Robert F LaPrade
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-03-21       Impact factor: 4.342

5.  Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate.

Authors:  Peini Chao; Bryan P Conrad; Daniel D Lewis; MaryBeth Horodyski; Antonio Pozzi
Journal:  BMC Vet Res       Date:  2013-06-24       Impact factor: 2.741

6.  Late-Onset Screw Migration into Iliac Vessels 21 years after Hip Arthrodesis.

Authors:  Taishi Hirai; Yutaka Inaba; Naomi Kobayashi; Shu Takakagawa; Yohei Yukizawa; Hiroyuki Ike; Tomoyuki Saito
Journal:  Clin Med Insights Case Rep       Date:  2014-10-06

7.  Suture-Only Repair Versus Suture Anchor-Augmented Repair for Achilles Tendon Ruptures With a Short Distal Stump: A Biomechanical Comparison.

Authors:  Michael A Boin; Matthew A Dorweiler; Christopher J McMellen; Gregory C Gould; Richard T Laughlin
Journal:  Orthop J Sports Med       Date:  2017-01-04

8.  Supplemental cerclage wiring in angle stable plate fixation of distal tibial spiral fractures enables immediate post-operative full weight-bearing: a biomechanical analysis.

Authors:  Sabrina Sandriesser; Stefan Förch; Edgar Mayr; Falk Schrödl; Christian von Rüden; Peter Augat
Journal:  Eur J Trauma Emerg Surg       Date:  2020-09-28       Impact factor: 3.693

Review 9.  Biomechanical analysis of fixation methods in acetabular fractures: a systematic review of test setups.

Authors:  Nico Hinz; Julius Dehoust; Matthias Münch; Klaus Seide; Tobias Barth; Arndt-Peter Schulz; Karl-Heinz Frosch; Maximilian J Hartel
Journal:  Eur J Trauma Emerg Surg       Date:  2022-03-19       Impact factor: 2.374

10.  Comparison of reamed long and short intramedullary nail constructs in unstable intertrochanteric femur fractures: A biomechanical study.

Authors:  Laura E Blum; Michael A Yee; Cyril Mauffrey; James A Goulet; Aaron M Perdue; Mark E Hake
Journal:  OTA Int       Date:  2020-05-05