Literature DB >> 22302256

Comparison of rates of reported adverse events associated with i.v. iron products in the United States.

George R Bailie.   

Abstract

PURPOSE: An analysis of reported adverse events (AEs) among patients using i.v. iron products, including the newer agent ferumoxytol, is presented.
METHODS: All AE reports to the Food and Drug Administration (FDA) citing iron sucrose, ferric gluconate, high- and low-molecular-weight iron dextran products, or ferumoxytol from October 2009 through June 2010 were evaluated. The rates of various classifications of reported AEs were calculated on a per-unit-sold basis and, for comparison of products supplied in different unit sizes, also in terms of 100-mg dose equivalents (DEq) of iron.
RESULTS: A total of 197 reported AEs were identified (a cumulative rate of 14.1 AEs per million units sold). The rates of all AE classifications combined ranged from 5.25 to 746 per million units sold for iron sucrose and ferumoxytol, respectively; using the other method of calculation, the rates ranged from 5.24 per million DEq (iron sucrose) to 147 per million DEq (ferumoxytol). Relative to iron sucrose and sodium ferric gluconate, ferumoxytol was associated with significantly elevated risks of death (odds ratio [OR], 475 and 156, respectively; p < 0.0001), serious nonfatal AEs (OR, 263 and 121, respectively; p < 0.0001), and all evaluated AE classifications combined (OR, 142 and 109, respectively; p < 0.05).
CONCLUSION: Analysis of reports submitted to FDA revealed large differences among i.v. iron products in reported deaths, serious AEs, other major AEs, and other AEs. Iron sucrose and sodium ferric gluconate were associated with much lower rates of AEs per million units sold than iron dextran or ferumoxytol, which were associated with the highest rates of all reported AE classifications.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22302256     DOI: 10.2146/ajhp110262

Source DB:  PubMed          Journal:  Am J Health Syst Pharm        ISSN: 1079-2082            Impact factor:   2.637


  30 in total

1.  Double bull's eye for post-operative intravenous iron in patient blood management: better outcome and cost-effective.

Authors:  Giancarlo M Liumbruno; Gioia Grazzini
Journal:  Blood Transfus       Date:  2013-12-04       Impact factor: 3.443

Review 2.  A comprehensive literatures update of clinical researches of superparamagnetic resonance iron oxide nanoparticles for magnetic resonance imaging.

Authors:  Yì Xiáng J Wáng; Jean-Marc Idée
Journal:  Quant Imaging Med Surg       Date:  2017-02

3.  Impact of European medicines agency recommendations for hypersensitivity reactions on intravenous iron prescription in haemodialysis centres of the Lombardy region.

Authors:  Rodolfo F Rivera; Davide Guido; Lucia Del Vecchio; Enzo Corghi; Marco D'Amico; Corrado Camerini; Donatella Spotti; Andrea Galassi; Claudio Pozzi; Giovanni Cancarini; Giuseppe Pontoriero; Francesco Locatelli
Journal:  J Nephrol       Date:  2015-12-29       Impact factor: 3.902

4.  Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol-enhanced 4D flow MRI.

Authors:  Kate Hanneman; Aya Kino; Joseph Y Cheng; Marcus T Alley; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2016-02-12       Impact factor: 4.813

5.  Adverse event reporting patterns of newly approved drugs in the USA in 2006: an analysis of FDA Adverse Event Reporting System data.

Authors:  Pankdeep Chhabra; Xing Chen; Sheila R Weiss
Journal:  Drug Saf       Date:  2013-11       Impact factor: 5.606

6.  Hypersensitivity reactions to intravenous iron: guidance for risk minimization and management.

Authors:  David Rampton; Joergen Folkersen; Steven Fishbane; Michael Hedenus; Stefanie Howaldt; Francesco Locatelli; Shalini Patni; Janos Szebeni; Guenter Weiss
Journal:  Haematologica       Date:  2014-11       Impact factor: 9.941

Review 7.  Molecular imaging of cerebrovascular lesions.

Authors:  Nohra Chalouhi; Pascal Jabbour; Vincent Magnotta; David Hasan
Journal:  Transl Stroke Res       Date:  2013-10-23       Impact factor: 6.829

8.  Oral Iron Therapy for Heart Failure With Reduced Ejection Fraction: Design and Rationale for Oral Iron Repletion Effects on Oxygen Uptake in Heart Failure.

Authors:  Gregory D Lewis; Marc J Semigran; Michael M Givertz; Rajeev Malhotra; Kevin J Anstrom; Adrian F Hernandez; Monica R Shah; Eugene Braunwald
Journal:  Circ Heart Fail       Date:  2016-05       Impact factor: 8.790

Review 9.  Hypersensitivity to intravenous iron: classification, terminology, mechanisms and management.

Authors:  J Szebeni; S Fishbane; M Hedenus; S Howaldt; F Locatelli; S Patni; D Rampton; G Weiss; J Folkersen
Journal:  Br J Pharmacol       Date:  2015-10-25       Impact factor: 8.739

10.  4D flow vs. 2D cardiac MRI for the evaluation of pulmonary regurgitation and ventricular volume in repaired tetralogy of Fallot: a retrospective case control study.

Authors:  Kimberley G Jacobs; Frandics P Chan; Joseph Y Cheng; Shreyas S Vasanawala; Shiraz A Maskatia
Journal:  Int J Cardiovasc Imaging       Date:  2020-01-01       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.