Literature DB >> 22301848

Comparison of contrast media and low-molecular-weight dextran for frequency-domain optical coherence tomography.

Yuichi Ozaki1, Hironori Kitabata, Hiroto Tsujioka, Seiki Hosokawa, Manabu Kashiwagi, Kohei Ishibashi, Kenichi Komukai, Takashi Tanimoto, Yasushi Ino, Shigeho Takarada, Takashi Kubo, Keizo Kimura, Atsushi Tanaka, Kumiko Hirata, Masato Mizukoshi, Toshio Imanishi, Takashi Akasaka.   

Abstract

BACKGROUND: Although an intracoronary frequency-domain optical coherence tomography (FD-OCT) system overcomes several limitations of the time-domain OCT (TD-OCT) system, the former requires injection of contrast media for image acquisition. The increased total amount of contrast media for FD-OCT image acquisition may lead to the impairment of renal function. The safety and usefulness of the non-occlusion method with low-molecular-weight dextran L (LMD-L) via a guiding catheter for TD-OCT image acquisition have been reported previously. The aim of the present study was to compare the image quality and quantitative measurements between contrast media and LMD-L for FD-OCT image acquisition in coronary stented lesions. METHODS AND
RESULTS: Twenty-two patients with 25 coronary stented lesions were enrolled in this study. FD-OCT was performed with the continuous-flushing method via a guiding catheter. Both contrast media and LMD-L were infused at a rate of 4 ml/s by an autoinjector. With regard to image quality, the prevalence of clear image segments was comparable between contrast media and LMD-L (97.9% vs. 96.5%, P=0.90). Furthermore, excellent correlations were observed between both flushing solutions in terms of minimum lumen area, mean lumen area, and mean stent area. The total volumes of contrast media and of LMD-L needed for OCT image acquisition were similar.
CONCLUSIONS: FD-OCT image acquisition with LMD-L has the potential to reduce the total amount of contrast media without loss of image quality.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22301848     DOI: 10.1253/circj.cj-11-1122

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  19 in total

1.  Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.

Authors:  Daisuke Izumi; Masatoshi Miyahara; Naoki Fujimoto; Shusuke Fukuoka; Masataka Sakai; Kaoru Dohi; Masaaki Ito
Journal:  Heart Vessels       Date:  2015-09-03       Impact factor: 2.037

2.  An assessment of the quality of optical coherence tomography image acquisition.

Authors:  Elder Iarossi Zago; Abdul Jawwad Samdani; Gabriel Tensol Rodrigues Pereira; Armando Vergara-Martel; Mohamad Amer Alaiti; Luis Augusto Dallan; Patricia Ely Pizzato; Vladislav Zimin; Anas Fares; Hiram G Bezerra
Journal:  Int J Cardiovasc Imaging       Date:  2020-02-18       Impact factor: 2.357

3.  Optimal flushing agents for integrated optical and acoustic imaging systems.

Authors:  Jiawen Li; Hataka Minami; Earl Steward; Teng Ma; Dilbahar Mohar; Claire Robertson; Kirk Shung; Qifa Zhou; Pranav Patel; Zhongping Chen
Journal:  J Biomed Opt       Date:  2015-05       Impact factor: 3.170

4.  Confirmation of jailed side-branch ostium in coronary bifurcation intervention by stent-oriented three-dimensional intravascular ultrasound.

Authors:  Fumiaki Nakao
Journal:  Cardiol J       Date:  2019       Impact factor: 2.737

Review 5.  Optical coherence tomography-guided percutaneous coronary intervention: a review of current clinical applications.

Authors:  Kazumasa Kurogi; Masanobu Ishii; Nobuyasu Yamamoto; Kenshi Yamanaga; Kenichi Tsujita
Journal:  Cardiovasc Interv Ther       Date:  2021-01-17

6.  Optical coherence tomography: influence of contrast concentration on image quality and diagnostic confidence.

Authors:  Florian Blachutzik; Stephan Achenbach; Holger Nef; Christian Hamm; Oliver Dörr; Niklas Boeder; Mohamed Marwan; Monique Tröbs; Reinhard Schneider; Jens Röther; Christian Schlundt
Journal:  Heart Vessels       Date:  2016-11-09       Impact factor: 2.037

7.  Frequency-domain optical coherence tomography assessment of human carotid atherosclerosis using saline flush for blood clearance without balloon occlusion.

Authors:  C A Given; G F Attizzani; M R Jones; C N Ramsey; W H Brooks; M A Costa; H G Bezerra
Journal:  AJNR Am J Neuroradiol       Date:  2013-02-07       Impact factor: 3.825

8.  Integrated intravascular ultrasound and optical coherence tomography technology: a promising tool to identify vulnerable plaques [INVITED PAPER].

Authors:  Jiawen Li; Zhongping Chen
Journal:  J Biomed Photonics Eng       Date:  2016-02-01

9.  In vivo label-free structural and biochemical imaging of coronary arteries using an integrated ultrasound and multispectral fluorescence lifetime catheter system.

Authors:  Julien Bec; Jennifer E Phipps; Dimitris Gorpas; Dinglong Ma; Hussain Fatakdawala; Kenneth B Margulies; Jeffrey A Southard; Laura Marcu
Journal:  Sci Rep       Date:  2017-08-21       Impact factor: 4.379

Review 10.  Research and clinical applications of optical coherence tomography in invasive cardiology: a review.

Authors:  Luigi Vignali; Emilia Solinas; Enzo Emanuele
Journal:  Curr Cardiol Rev       Date:  2014-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.