Literature DB >> 22301180

Variation of the superelastic properties and nickel release from original and reused NiTi orthodontic archwires.

F J Gil1, E Espinar, J M Llamas, J M Manero, M P Ginebra.   

Abstract

Reuse of NiTi orthodontic wires has become increasingly common in dental clinics. For sterilization and recovery of the original superelastic properties of the wires, a heat treatment is usually performed between 500 and 600 °C. The aim of this study was to analyze the effect of these thermal treatments on the mechanical behavior and the microstructure of NiTi archwires of different compositions. A reduction of the Ni content was observed in the matrix of the thermally treated archwires, due to the formation of Ti(3)Ni(4) precipitates. The nickel-rich precipitates were observed and characterized by Transmission Electron Microscopy (TEM) and electron diffraction. They were found to alter the mechanical properties of the wires, decreasing the transformation stresses, and causing a loss of activation of the NiTi archwires. The release of nickel was higher in the original archwires than in the reused ones, due to the matrix nickel depletion caused by the precipitation of Ti(3)Ni(4).
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22301180     DOI: 10.1016/j.jmbbm.2011.11.005

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

1.  Mechanism of fracture of NiTi superelastic endodontic rotary instruments.

Authors:  Javier Gil; Elisa Rupérez; Eugenio Velasco; Conrado Aparicio; José María Manero
Journal:  J Mater Sci Mater Med       Date:  2018-08-07       Impact factor: 3.896

2.  An evaluation of two types of nickel-titanium wires in terms of micromorphology and nickel ions' release following oral environment exposure.

Authors:  Abdul Razzak A Ghazal; Mohammad Y Hajeer; Rabab Al-Sabbagh; Ibrahim Alghoraibi; Ahmad Aldiry
Journal:  Prog Orthod       Date:  2015-05-20       Impact factor: 2.750

3.  Evaluation of the release of nickel and titanium under orthodontic treatment.

Authors:  Rafael Velasco-Ibáñez; Edith Lara-Carrillo; Raúl Alberto Morales-Luckie; Elizabeth Teresita Romero-Guzmán; Víctor Hugo Toral-Rizo; Marius Ramírez-Cardona; Verónica García-Hernández; Carlo Eduardo Medina-Solís
Journal:  Sci Rep       Date:  2020-12-17       Impact factor: 4.379

4.  Effect of Fluoride Content of Mouthwashes on Superelastic Properties of NiTi Orthodontic Archwires.

Authors:  Francisco Pastor; Juan Carlos Rodríguez; José María Barrera; José Angel Delgado García-Menocal; Aritza Brizuela; Andreu Puigdollers; Eduardo Espinar; Javier Gil
Journal:  Materials (Basel)       Date:  2022-09-22       Impact factor: 3.748

Review 5.  A Critical Appraisal of the Use and Properties of Nickel-Titanium Dental Alloys.

Authors:  Petra Močnik; Tadeja Kosec
Journal:  Materials (Basel)       Date:  2021-12-18       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.