Literature DB >> 22300627

Assessment of the relationship between Contegra conduit size and early valvar insufficiency.

Katja M Gist1, Max B Mitchell, James Jaggers, Dave N Campbell, Jessica A Yu, Bruce F Landeck.   

Abstract

BACKGROUND: Contegra bovine jugular vein (BJV) conduit results vary widely, and little attention has been directed at assessment of early conduit insufficiency. Conduit insufficiency is graded subjectively, and criteria vary. Several studies have used branch pulmonary artery flow reversal (BPAFR) to define severe conduit insufficiency. BJV valves are larger than human pulmonary valves of similar diameter. We hypothesize that anatomic differences between BJV and human pulmonary valves limit the use of BPAFR in the evaluation of BJV competence. Our purposes were to (1) assess the prevalence of early and 6-month BJV conduit insufficiency in our patients, (2) determine if conduit size affects BJV competence, and (3) determine if BPAFR is a specific discriminator of severe conduit insufficiency.
METHODS: We reviewed 135 BJV conduits. One cardiologist blinded to original reports reviewed postoperative and 6-month echocardiograms. Conduits were grouped by size: group 1, 12 to 14 mm (n=51), and group 2, 16 to 22 mm (n=84). Moderate or greater insufficiency was considered clinically significant.
RESULTS: Early conduit insufficiency was common in group 1 (37%) and rare in group 2 (5%, p<0.0001). After excluding conduits with significant insufficiency, BPAFR occurred in 18% (group 1, 27%; group 2, 13%; p=0.02). At follow-up, insufficiency worsened in group 1 but was stable in group 2.
CONCLUSIONS: Early conduit insufficiency is common and worsens with follow-up in small BJVs. Conduit insufficiency is limited in larger sizes and remains stable. BJV exhibits BPAFR commonly in the absence of significant conduit insufficiency. BPAFR should not be used as a primary criterion for grading insufficiency in BJV conduits.
Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22300627     DOI: 10.1016/j.athoracsur.2011.10.057

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  Early clinical outcomes of right ventricular outflow tract reconstruction with small caliber bovine jugular vein conduit (Contegra®) in small children.

Authors:  Takashi Kido; Takaya Hoashi; Koji Kagisaki; Toshiki Fujiyoshi; Masataka Kitano; Kenichi Kurosaki; Isao Shiraishi; Toshikatsu Yagihara; Yoshiki Sawa; Hajime Ichikawa
Journal:  J Artif Organs       Date:  2016-05-28       Impact factor: 1.731

2.  Mid-term outcomes of Contegra implantation for the reconstruction of the right ventricular outflow tract to proximal branch pulmonary arteries: Japan multicentre study.

Authors:  Takaya Hoashi; Hajime Ichikawa; Keiichi Hirose; Naohiro Horio; Takahisa Sakurai; Hironori Matsuhisa; Yoshihiro Ohsima; Hajime Sakurai; Shingo Kasahara; Kisaburo Sakamoto
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-07-26

Review 3.  Current development of bovine jugular vein conduit for right ventricular outflow tract reconstruction.

Authors:  Chenggang Li; Bo Xie; Ruizhe Tan; Lijin Liang; Zhaoxiang Peng; Qi Chen
Journal:  Front Bioeng Biotechnol       Date:  2022-08-04

4.  Risk factors for early adverse outcomes after bovine jugular vein conduit implantation: influence of oversized conduit on the outcomes.

Authors:  Dong-Hee Kim; Young Kern Kwon; Eun Seok Choi; Bo Sang Kwon; Chun Soo Park; Tae-Jin Yun
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-09-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.