Literature DB >> 22299100

Implant-supported first molar restorations: correlation of finite element analysis with clinical outcomes.

Zeev Ormianer1, Ady Palti, Burak Demiralp, Guillaume Heller, Israel Lewinstein, Philippe G Khayat.   

Abstract

PURPOSE: This study aimed to evaluate the effect of the placement of wide-diameter implants on bone stress concentrations and marginal bone loss in the first molar region. Study hypotheses held that increasing implant diameter would decrease peri-implant bone stress levels, but that statistically significant reductions in clinical bone loss would either (1) not be observed for any implant diameter or (2) be observed only for the widest implant diameter.
MATERIALS AND METHODS: Three-dimensional finite element analysis (3D FEA) was used to analyze the relationship between implant diameter and peri-implant bone thickness, cortical bone thickness, occlusal load direction, and percentage of boneto-implant contact on bone stress levels in the first molar region. A retrospective review of patient records was also conducted in three private practices to assess clinical outcomes and bone level changes around one implant design in three diameters (3.7, 4.7, and 6.0 mm) placed in first molar locations. Categorical variable summaries and comparisons of 3D FEA and clinical findings were made using the FREQ procedure, t test procedures (Student t tests, folded F tests, Satterthwaite t tests), and the NONPAR1WAY procedure (Wilcoxon nonparametric test).
RESULTS: Cumulative implant success was 98.4% and survival was 98% after a mean of 49.2 months. Although increasing implant diameter always reduced peri-implant stress concentrations in 3D FEA experiments, clinically, only 6.0-mm implants exhibited a statistically significant reduction in bone loss (0 mm) as compared to 3.7-mm and 4.7-mm implants.
CONCLUSION: Only 6.0-mm implants were effective in reducing marginal bone loss in the first molar region. 3D FEA results supported previous clinical findings that maintaining approximately 1.8 mm of buccal plate thickness can help reduce bone stress concentrations and preserve buccal bone height. A history of periodontitis may adversely affect long-term marginal bone stability.

Entities:  

Mesh:

Year:  2012        PMID: 22299100

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Influence of Inter-Radicular Septal Bone Quantity in Primary Stability of Immediate Molar Implants with Different Length and Diameter Placed in Mandibular Region. A Cone-Beam Computed Tomography-Based Simulated Implant Study.

Authors:  Arshad Jamal Sayed; Safia Shoeb Shaikh; Shoeb Yakub Shaikh; Mohammed Abid Hussain; Sabahat Ullah Khan Tareen; Vaibhav Awinashe
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

Review 2.  The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies.

Authors:  Julius Maminskas; Algirdas Puisys; Ritva Kuoppala; Aune Raustia; Gintaras Juodzbalys
Journal:  J Oral Maxillofac Res       Date:  2016-09-09

3.  Inter radicular bone dimensions in primary stability of immediate molar implants - A cone beam computed tomography retrospective analysis.

Authors:  Arshad Jamal Sayed; Safia Shoeb Shaikh; Shoeb Yakub Shaikh; Mohammed Aabid Hussain
Journal:  Saudi Dent J       Date:  2021-04-09

4.  A Comparative Evaluation of the Strain Transmitted through Prostheses on Implants with Two Different Macro-Structures and Connection during Insertion and Loading Phase: An In Vitro Study.

Authors:  Riyam Kassem; Amar Samara; Ameer Biadsee; Shchada Masarwa; Tarek Mtanis; Zeev Ormianer
Journal:  Materials (Basel)       Date:  2022-07-16       Impact factor: 3.748

5.  Consecutive Case Series of Healed Single-Molar Sites Immediately Restored with Wide-Diameter Implants: A 1-Year Evaluation.

Authors:  Hadi Antoun; Pierre Cherfane; Bouchra Sojod
Journal:  Int J Dent       Date:  2016-04-18

6.  A 3-year prospective randomized clinical trial of alveolar bone crest response and clinical parameters through 1, 2, and 3 years of clinical function of implants placed 4 months after alveolar ridge preservation using two different allogeneic bone-grafting materials.

Authors:  Önder Solakoğlu; Duygu Ofluoğlu; Heidi Schwarzenbach; Guido Heydecke; Daniel Reißmann; Sertan Ergun; Werner Götz
Journal:  Int J Implant Dent       Date:  2022-02-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.