Literature DB >> 2229795

Plaque morphology and pathologic changes in arteries from patients dying after coronary balloon angioplasty.

A Farb1, R Virmani, J B Atkinson, F D Kolodgie.   

Abstract

Morphologic correlates of pathologic success or failure were studied at autopsy in 28 patients with 40 coronary arteries that had been subjected to balloon angioplasty. The presence of the following histologic features was evaluated: plaque concentricity or eccentricity, calcification, fibrous or fibropultaceous plaque, medial disruption, luminal thrombus and inflammation. Angioplasty was considered successful (residual cross-sectional luminal area greater than 25%) on pathologic examination in 14 arteries and unsuccessful in 26 arteries. Eccentric plaques were more likely to be successfully dilated than were concentric lesions (p less than 0.05). Six (50%) of 12 fibropultaceous plaques were successfully dilated compared with only 8 (29%) of 28 fibrous plaques. Moderate to severe calcification did not preclude morphologic success. Medial stretching or dissection, or both, was more often associated with a successful result. Thus, plaque morphology may be an important determinant of pathologic outcome after coronary angioplasty.

Entities:  

Mesh:

Year:  1990        PMID: 2229795     DOI: 10.1016/0735-1097(90)90386-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  9 in total

1.  Dynamics of Vascular Remodeling: An Overview and Bibliography.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1996       Impact factor: 2.300

2.  Strategic targeting of atherosclerotic lesions.

Authors:  J Narula; R Virmani; A E Iskandrian
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

Review 3.  In stent restenosis: bane of the stent era.

Authors:  A K Mitra; D K Agrawal
Journal:  J Clin Pathol       Date:  2006-03       Impact factor: 3.411

4.  Molecular atherectomy for restenosis.

Authors:  W Casscells; D A Lappi; A Baird
Journal:  Trends Cardiovasc Med       Date:  1993 Nov-Dec       Impact factor: 6.677

5.  Selective deposits of versican in the extracellular matrix of restenotic lesions from human peripheral arteries.

Authors:  T N Wight; S Lara; R Riessen; R Le Baron; J Isner
Journal:  Am J Pathol       Date:  1997-10       Impact factor: 4.307

6.  Multi-modality imaging for stent edge assessment.

Authors:  Soe Hee Ann; Kyung Hun Lim; Cai De Jin; Eun-Seok Shin
Journal:  Heart Vessels       Date:  2014-01-31       Impact factor: 2.037

7.  Intravascular ultrasound-guided troubleshooting in a large hematoma treated with fenestration using a cutting balloon.

Authors:  Hye Jin Noh; Jin-Ho Choi; Young Bin Song; Hyun Chul Jo; Ji Hyun Yang; Sang Min Kim; Hyun Jong Lee; Joon Hyuk Choi; Soo Hee Choi; Joo Yong Hahn; Seung Hyuk Choi; Hyeon Cheol Gwon
Journal:  Korean Circ J       Date:  2009-04-28       Impact factor: 3.243

8.  Effects of local delivery of trapidil on neointima formation in a rabbit angioplasty model.

Authors:  K Zacharowski; D Schneidmüller; W Ibe; T Grosser; M Buerke; J Meyer; H Darius
Journal:  Br J Pharmacol       Date:  2000-02       Impact factor: 8.739

Review 9.  Restenosis following coronary angioplasty: current status.

Authors:  M K Hong
Journal:  Korean J Intern Med       Date:  2001-06       Impact factor: 2.884

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.