Literature DB >> 22297495

Nintendo Wii remote controllers for head posture measurement: accuracy, validity, and reliability of the infrared optical head tracker.

Jongshin Kim1, Kyoung Won Nam, Ik Gyu Jang, Hee Kyung Yang, Kwang Gi Kim, Jeong-Min Hwang.   

Abstract

PURPOSE: To evaluate the accuracy, validity, and reliability of a newly developed infrared optical head tracker (IOHT) using Nintendo Wii remote controllers (WiiMote; Nintendo Co. Ltd., Kyoto, Japan) for measurement of the angle of head posture.
METHODS: The IOHT consists of two infrared (IR) receivers (WiiMote) that are fixed to a mechanical frame and connected to a monitoring computer via a Bluetooth communication channel and an IR beacon that consists of four IR light-emitting diodes (LEDs). With the use of the Cervical Range of Motion (CROM; Performance Attainment Associates, St. Paul, MN) as a reference, one- and three-dimensional (1- and 3-D) head postures of 20 normal adult subjects (20-37 years of age; 9 women and 11 men) were recorded with the IOHT.
RESULTS: In comparison with the data from the CROM, the IOHT-derived results showed high consistency. The measurements of 1- and 3-D positions of the human head with the IOHT were very close to those of the CROM. The correlation coefficients of 1- and 3-D positions between the IOHT and the CROM were more than 0.99 and 0.96 (P < 0.05, Pearson's correlation test), respectively. Reliability tests of the IOHT for the normal adult subjects for 1- and 3-D positions of the human head had 95% limits of agreement angles of approximately ±4.5° and ±8.0°, respectively.
CONCLUSIONS: The IOHT showed strong concordance with the CROM and relatively good test-retest reliability, thus proving its validity and reliability as a head-posture-measuring device. Considering its high performance, ease of use, and low cost, the IOHT has the potential to be widely used as a head-posture-measuring device in clinical practice.

Entities:  

Mesh:

Year:  2012        PMID: 22297495     DOI: 10.1167/iovs.11-8329

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  6 in total

1.  Accuracy, validity, and reliability of the infrared optical head tracker (IOHT).

Authors:  Siamak Sabour; Fariba Ghassemi
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-07-13       Impact factor: 4.799

2.  Therapeutic Uses of Active Videogames: A Systematic Review.

Authors:  Amanda E Staiano; Rachel Flynn
Journal:  Games Health J       Date:  2014-09-16

3.  Characterization of the head-to-trunk orientation with handheld optical 3D apparatus based on the fringe projection technique.

Authors:  Urban Pavlovčič; Janez Diaci; Janez Možina; Matija Jezeršek
Journal:  Biomed Eng Online       Date:  2013-09-26       Impact factor: 2.819

4.  The Cambridge Face Tracker: Accurate, Low Cost Measurement of Head Posture Using Computer Vision and Face Recognition Software.

Authors:  Peter B M Thomas; Tadas Baltrušaitis; Peter Robinson; Anthony J Vivian
Journal:  Transl Vis Sci Technol       Date:  2016-09-30       Impact factor: 3.283

5.  Is a Depth Camera in Agreement with an Electromagnetic Tracking Device when Measuring Head Position?

Authors:  Vienna-Jaye Burchell; Gemma Arblaster; David Buckley; Jonathan Wheat
Journal:  Br Ir Orthopt J       Date:  2021-11-15

6.  Test-retest reliability of Kinect's measurements for the evaluation of upper body recovery of stroke patients.

Authors:  A Mobini; S Behzadipour; M Saadat
Journal:  Biomed Eng Online       Date:  2015-08-04       Impact factor: 2.819

  6 in total