Literature DB >> 22296869

Removing ECG contamination from EMG recordings: a comparison of ICA-based and other filtering procedures.

Nienke W Willigenburg1, Andreas Daffertshofer, Idsart Kingma, Jaap H van Dieën.   

Abstract

Trunk muscle electromyography (EMG) is often contaminated by the electrocardiogram (ECG), which hampers data analysis and potentially yields misinterpretations. We propose the use of independent component analysis (ICA) for removing ECG contamination and compared it with other procedures previously developed to decontaminate EMG. To mimic realistic contamination while having uncontaminated reference signals, we employed EMG recordings from peripheral muscles with different activation patterns and superimposed distinct ECG signals that were recorded during rest at conventional locations for trunk muscle EMG. ICA decomposition was performed with and without a separately collected ECG signal as part of the data set and contaminated ICA modes representing ECG were identified automatically. Root mean squared relative errors and correlations between the linear envelopes of uncontaminated and contaminated EMG were calculated to assess filtering effects on EMG amplitude. Changes in spectral content were quantified via mean power frequencies. ICA-based filtering largely preserved the EMG's spectral content. Performance on amplitude measures was especially successful when a separate ECG recording was included. That is, the ICA-based filtering can produce excellent results when EMG and ECG are indeed statistically independent and when mode selection is flexibly adjusted to the data set under study.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22296869     DOI: 10.1016/j.jelekin.2012.01.001

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  17 in total

1.  Use of Chest Wall Electromyography to Detect Respiratory Effort during Polysomnography.

Authors:  Richard B Berry; Scott Ryals; Ankur Girdhar; Mary H Wagner
Journal:  J Clin Sleep Med       Date:  2016-09-15       Impact factor: 4.062

2.  Semi-automated Detection of Polysomnographic REM Sleep without Atonia (RSWA) in REM Sleep Behavioral Disorder.

Authors:  Iva Milerska; Vaclav Kremen; Vaclav Gerla; Erik K St Louis; Lenka Lhotska
Journal:  Biomed Signal Process Control       Date:  2019-03-07       Impact factor: 3.880

3.  Four-week exercise program does not change rotator cuff muscle activation and scapular kinematics in healthy subjects.

Authors:  Yin-Liang Lin; Andrew Karduna
Journal:  J Orthop Res       Date:  2016-04-13       Impact factor: 3.494

4.  A novel technique for muscle onset detection using surface EMG signals without removal of ECG artifacts.

Authors:  Ping Zhou; Xu Zhang
Journal:  Physiol Meas       Date:  2013-12-17       Impact factor: 2.833

5.  Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

Authors:  Ryan J Marker; Katrina S Maluf
Journal:  J Electromyogr Kinesiol       Date:  2014-08-27       Impact factor: 2.641

Review 6.  EMG Processing Based Measures of Fatigue Assessment during Manual Lifting.

Authors:  E F Shair; S A Ahmad; M H Marhaban; S B Mohd Tamrin; A R Abdullah
Journal:  Biomed Res Int       Date:  2017-02-19       Impact factor: 3.411

7.  Muscle Synergies in Children Walking and Running on a Treadmill.

Authors:  Margit M Bach; Andreas Daffertshofer; Nadia Dominici
Journal:  Front Hum Neurosci       Date:  2021-05-10       Impact factor: 3.169

Review 8.  Surface electromyography signal processing and classification techniques.

Authors:  Rubana H Chowdhury; Mamun B I Reaz; Mohd Alauddin Bin Mohd Ali; Ashrif A A Bakar; K Chellappan; T G Chang
Journal:  Sensors (Basel)       Date:  2013-09-17       Impact factor: 3.576

9.  Design, development and testing of a low-cost sEMG system and its use in recording muscle activity in human gait.

Authors:  Tamara Grujic Supuk; Ana Kuzmanic Skelin; Maja Cic
Journal:  Sensors (Basel)       Date:  2014-05-07       Impact factor: 3.576

10.  FastICA peel-off for ECG interference removal from surface EMG.

Authors:  Maoqi Chen; Xu Zhang; Xiang Chen; Mingxing Zhu; Guanglin Li; Ping Zhou
Journal:  Biomed Eng Online       Date:  2016-06-13       Impact factor: 2.819

View more