Literature DB >> 22296842

Matched comparison of rotational stability of 1-piece acrylic and plate-haptic silicone toric intraocular lenses in Asian eyes.

Wei-Han Chua1, Leonard H Yuen, Jocelyn Chua, Gillian Teh, Warren E Hill.   

Abstract

PURPOSE: To evaluate and compare the postoperative rotational stability of a 1-piece acrylic toric intraocular lens (IOL) (Acrysof) and a plate-haptic silicone toric IOL (Staar) in Asian eyes.
SETTING: Singapore National Eye Centre, Singapore.
DESIGN: Prospective randomized control trial.
METHODS: Eyes of Chinese patients having cataract surgery were randomized to receive the acrylic toric IOL or the silicone toric IOL. Postoperatively, patients returned at 1 day, 1 week, and 1 and 3 months. The eyes were dilated and slitlamp retroillumination photography of the toric IOL was performed to assess rotational stability.
RESULTS: The acrylic IOL was implanted in 24 eyes and the silicone IOL in 26 eyes. The mean age of the patients was 68.2 years (range 42 to 82 years). The mean IOL rotation from baseline to 3 months postoperatively was 4.23 ± 4.28 degrees in the acrylic IOL group and 9.42 ± 7.80 degrees in the silicone IOL group; the difference was statistically significant (P=.01). Of the acrylic IOLs, 73% were rotated less than 5 degrees at 3 months; none was rotated more than 15 degrees at 3 months. The silicone toric IOLs showed greater rotational movement, with 37% being rotated less than 5 degrees and 21% being rotated more than 15 degrees.
CONCLUSION: The acrylic toric IOL had better rotational stability than the silicone toric IOL.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22296842     DOI: 10.1016/j.jcrs.2011.10.037

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  An easy and practical method for toric intraocular lens implantation: marking corneal astigmatic axis at slit-lamp.

Authors:  Huseyin Bayramlar; Yaşar Dag; Remzi Karadag; Ozgur Cakici
Journal:  Int Ophthalmol       Date:  2016-05-12       Impact factor: 2.031

2.  Cataract Surgery in Eyes with Low Corneal Astigmatism: Implantation of the Acrysof IQ Toric SN6AT2 Intraocular Lens.

Authors:  Jaskirat S Aujla; Stephen J Vincent; Shane White; Jai Panchapakesan
Journal:  J Ophthalmic Vis Res       Date:  2014 Jul-Sep

3.  Astigmatism management in cataract surgery with Precizon(®) toric intraocular lens: a prospective study.

Authors:  Carolina Vale; Carlos Menezes; J Firmino-Machado; Pedro Rodrigues; Miguel Lume; Paula Tenedório; Pedro Menéres; Maria do Céu Brochado
Journal:  Clin Ophthalmol       Date:  2016-01-19

Review 4.  Premium intraocular lenses: The past, present and future.

Authors:  Jasmin Zvorničanin; Edita Zvorničanin
Journal:  J Curr Ophthalmol       Date:  2018-05-18

5.  Comparative effects of various types of toric intraocular lenses on astigmatism correction.

Authors:  Jayoon Moon; Chang Ho Yoon; Mee Kum Kim
Journal:  BMC Ophthalmol       Date:  2020-04-28       Impact factor: 2.209

6.  Rotation Characteristics of Three Toric Monofocal Intraocular Lenses.

Authors:  Brent A Kramer; David R Hardten; John P Berdahl
Journal:  Clin Ophthalmol       Date:  2020-12-16

7.  Comparative evaluation of two toric intraocular lenses for correcting astigmatism in patients undergoing phacoemulsification.

Authors:  Sheetal A Seth; Rakesh K Bansal; Parul Ichhpujani; Natasha G Seth
Journal:  Indian J Ophthalmol       Date:  2018-10       Impact factor: 1.848