Literature DB >> 22295870

The Size 1 ProSeal™ laryngeal mask airway in infants: a randomized, noncrossover study with the Classic™ laryngeal mask airway.

Maite López-Gil1, Ignacio Mantilla, Teresa Blanco, Enrique Teigell, Mónica Hervias, Rosa Fernández-López.   

Abstract

BACKGROUND: In recent years, numerous scientific publications have endorsed the superiority of the ProSeal™ laryngeal mask airway (PLMA) over the Classic™ laryngeal mask airway (cLMA) in adults, children, and infants. The PLMA forms a better seal for both the respiratory and gastrointestinal tracts, provides easier access to the gastrointestinal tract, and exerts lower mucosal pressures for a given seal pressure. This study aims to determine whether this superiority can also be observed for the size 1 PLMA used in anesthetized neonates and infants with positive pressure ventilation.
METHODS: Sixty consecutive neonates and infants undergoing elective surgical procedures were randomized to airway management with the size 1 PLMA or cLMA. For all patients, we recorded ease of insertion, effective airway time, number of placement attempts, oropharyngeal leak pressure, fiberoptic position, audible leaks, mask displacement, number of reinsertions during maintenance, gastric insufflation, and frequency of blood stain.
RESULTS: Ease of insertion, successful insertion in <3 attempts, fiberoptic position of the airway tube, and frequency of blood stain were similar in both groups. Effective airway time was lower for the PLMA group (30.5 vs 35.6 s). Oropharyngeal leak pressure was higher with the PLMA (32.9 vs 22.2 cm H(2)O, P < 0.001) and gastric insufflation less common (0% vs 6%, P = 0.492). There were fewer mask displacements during maintenance of anesthesia with the PLMA (0% vs 26.7%, P < 0.001). Mask reinsertion was not necessary during maintenance of anesthesia with the PLMA, although it was necessary in 14 cases in the cLMA group (0% vs 46%, P < 0.001). Audible leaks were less common with the PLMA (0% vs 46%, P < 0.001).
CONCLUSIONS: We conclude that the size 1 PLMA is a stable, safe, and efficacious airway control device during neonatal and infant anesthesia, allowing higher peak airway pressure during positive pressure ventilation, with fewer mask displacements and gastric insufflations than the cLMA.
© 2012 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22295870     DOI: 10.1111/j.1460-9592.2012.03801.x

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  4 in total

1.  Randomized evaluation of the size 2 laryngeal tube and classical laryngeal mask airway in different head and neck positions in children under positive pressure ventilation.

Authors:  Andreas Biedler; Marc Wrobel; Sven Schneider; Stefan Soltész; Stephan Ziegeler; Ulrich Grundmann
Journal:  J Anesth       Date:  2013-03-04       Impact factor: 2.078

2.  Performance of size 1 I-gel compared with size 1 ProSeal laryngeal mask in anesthetized infants and neonates.

Authors:  Gulay Erdogan Kayhan; Zekine Begec; Mukadder Sanli; Ender Gedik; Mahmut Durmus
Journal:  ScientificWorldJournal       Date:  2015-02-22

3.  Position of bite block in size 1 laryngeal mask airway ProSeal™ and stability during insertion.

Authors:  Sandeep Kumar Mishra; Anusha Cherian; Hemavathy Balchander; Niyaz C Ashraf
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2014-04

4.  Alternative Methods of Surfactant Administration in Preterm Infants with Respiratory Distress Syndrome: State of the Art.

Authors:  Ömer Erdeve; Emel Okulu; Kari D Roberts; Scott O Guthrie; Prem Fort; H Gözde Kanmaz Kutman; Peter A Dargaville
Journal:  Turk Arch Pediatr       Date:  2021-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.