Literature DB >> 22291058

Rapid and specific approach for direct measurement of glimepiride in human plasma by LC-ESI-MS-MS employing automated 96 well format: application to a bioequivalence study.

M L Kundlik1, B H Zaware, S R Kuchekar.   

Abstract

A rapid liquid chromatographic method with electrospray ionization tandem mass spectrometric (LC-MS-MS) detection is developed and validated for quantification of glimepiride in heparinized human plasma. Plasma samples, without a drying and reconstitution step, are extracted by solid-phase extraction (SPE) and eluted with 0.9 mL of acetonitrile-methanol (1:1, v/v) containing 0.05% formic acid. The analyte and glimepiride d8 (internal standard, IS) are chromatographed on a C(18) column; the mobile phase is acetonitrile-2 mm ammonium formate (88:12, v/v), with the pH adjusted to 3.5 with formic acid, at a flow rate of 0.5 mL/min. The retention times of glimepiride and the IS are 0.93 min, and the runtime is 1.6 min per sample. Selected reaction monitoring of MH(+) at m/z 491.20 and 499.26 result in stable fragment ions with m/z 351.80 and 359.96 for glimepiride and the IS, respectively. The response was a linear function of the concentration in the range of 2.0-650.0 ng/mL, with r ≥ 0.9994. The recovery of glimepiride and the IS ranged from 81.91 to 83.36%. The assay has excellent characteristics and has been successfully used for the analysis of glimepiride in healthy human subjects in a bioequivalence study. It was well suited to clinical studies of the drug involving large numbers of samples.
© The Author [2011]. Published by Oxford University Press. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22291058      PMCID: PMC3252129          DOI: 10.1093/chromsci/bmr005

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  13 in total

1.  Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry.

Authors:  Isam Ismail Salem; Jafer Idrees; Jaafar I Al Tamimi
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2004-01-05       Impact factor: 3.205

2.  Improved liquid chromatographic tandem mass spectrometric determination and pharmacokinetic study of glimepiride in human plasma.

Authors:  Constantinos Pistos; Maria Koutsopoulou; Irene Panderi
Journal:  Biomed Chromatogr       Date:  2005-06       Impact factor: 1.902

3.  Acidic and neutral drugs screen in blood with quantitation using microbore high-performance liquid chromatography-diode array detection and capillary gas chromatography-flame ionization detection.

Authors:  D S Lo; T C Chao; S E Ng-Ong; Y J Yao; T H Koh
Journal:  Forensic Sci Int       Date:  1997-12-01       Impact factor: 2.395

4.  Bioequivalence and pharmacokinetic evaluation of two formulations of glimepiride 2 mg: a single-dose, randomized-sequence, open-label, two-way crossover study in healthy Chinese male volunteers.

Authors:  Yun Liu; Meng-qi Zhang; Jian-min Zhu; Jing-ying Jia; Yan-mei Liu; Gang-yi Liu; Shuijun Li; Li-ping Weng; Chen Yu
Journal:  Clin Ther       Date:  2010-05       Impact factor: 3.393

5.  Capillary electrophoretic detection of metabolites in the urine of patients receiving hypoglycemic drug therapy.

Authors:  M E Roche; R P Oda; G M Lawson; J P Landers
Journal:  Electrophoresis       Date:  1997-09       Impact factor: 3.535

6.  A class-independent drug screen in forensic toxicology using a photodiode array detector.

Authors:  O H Drummer; A Kotsos; I M McIntyre
Journal:  J Anal Toxicol       Date:  1993 Jul-Aug       Impact factor: 3.367

7.  Analysis of glimepiride by using derivative UV spectrophotometric method.

Authors:  S Altinöz; D Tekeli
Journal:  J Pharm Biomed Anal       Date:  2001-01       Impact factor: 3.935

8.  Simultaneous determination of the sulphonylurea glimepiride and its metabolites in human serum and urine by high-performance liquid chromatography after pre-column derivatization.

Authors:  K H Lehr; P Damm
Journal:  J Chromatogr       Date:  1990-04-06

9.  Determination of glimepiride in human plasma using semi-microbore high performance liquid chromatography with column-switching.

Authors:  Yun-Kyoung Song; Jeong-Eun Maeng; Hye-Ryung Hwang; Jeong-Sook Park; Bae-Chan Kim; Jin-Ki Kim; Chong-Kook Kim
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2004-10-15       Impact factor: 3.205

10.  Detection of anti-diabetics in equine plasma and urine by liquid chromatography-tandem mass spectrometry.

Authors:  Emmie N M Ho; Kenneth C H Yiu; Terence S M Wan; Brian D Stewart; Keith L Watkins
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2004-11-05       Impact factor: 3.205

View more
  1 in total

1.  Rapid, Validated UPLC-MS/MS Method for Determination of Glibenclamide in Rat Plasma.

Authors:  Mohd Aftab Alam; Fahad Ibrahim Al-Jenoobi; Abdullah Mohammed Al-Mohizea
Journal:  Int J Anal Chem       Date:  2018-09-02       Impact factor: 1.885

  1 in total