Literature DB >> 22289473

The use of balloon-expandable stent grafts for the management of acute arterial bleeding.

Ulrike Stampfl1, Christof-Matthias Sommer, Nadine Bellemann, Jürgen Weitz, Dittmar Böckler, Götz Martin Richter, Hans-Ulrich Kauczor, Boris Radeleff.   

Abstract

PURPOSE: To evaluate the efficacy and safety of balloon-expandable stent grafts in the emergency treatment of acute arterial hemorrhage.
MATERIALS AND METHODS: Between July 2008 and December 2009, 15 patients with acute arterial hemorrhage from inflammatory vessel erosion or pseudoaneurysms (n = 9), noninflammatory pseudoaneurysms (n = 3), or iatrogenic vessel injury (n = 3) were treated with emergency stent graft implants. The primary study endpoints to determine treatment efficacy and safety were survival, complication rates, and freedom from recurrent hemorrhaging or reintervention. The secondary study endpoints were technical and clinical success.
RESULTS: The survival rate was 73% with a mean follow-up of 119 days ± 220. The complication rate was 20%. The procedure was technically successful in 13 of 15 (87%) patients. One endoleak persisted and led to a reintervention rate of 7%. The bleeding ceased immediately after stent graft implantation in 14 patients.
CONCLUSIONS: Implantation of balloon-expandable stent grafts is a safe and effective emergency treatment for acute arterial hemorrhage from visceral and peripheral vessels. Copyright Â
© 2012 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22289473     DOI: 10.1016/j.jvir.2011.12.010

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  3 in total

Review 1.  Bleeding complications after pancreatic surgery: interventional radiology management.

Authors:  Pierpaolo Biondetti; Enrico Maria Fumarola; Anna Maria Ierardi; Gianpaolo Carrafiello
Journal:  Gland Surg       Date:  2019-04

Review 2.  [Interventions for pancreatitis].

Authors:  K Dubasz; M Misbahuddin; C Graeb; B Radeleff
Journal:  Radiologe       Date:  2021-05-03       Impact factor: 0.635

3.  Emergency management of iatrogenic arterial injuries with a low-profile balloon-expandable stent-graft: Preliminary results.

Authors:  Maria Antonella Ruffino; Marco Fronda; Sara Varello; Andrea Discalzi; Andrea Mancini; Pierluigi Muratore; Denis Rossato; Laura Bergamasco; Dorico Righi; Paolo Fonio
Journal:  Medicine (Baltimore)       Date:  2020-04       Impact factor: 1.817