Literature DB >> 22288082

AccuO2 oximetry-driven oxygen-conserving device versus fixed-dose oxygen devices in stable COPD patients.

Kathryn L Rice1, Matthew F Schmidt, John S Buan, Francene Lebahn, Ted K Schwarzock.   

Abstract

BACKGROUND: Because standard home oxygen (O2) systems deliver O2 at fixed rates, these systems are not designed to ensure optimal oxygen delivery based on physiologic need. We tested the ability of the AccuO2 (OptiSat Medical, Minneapolis, Minnesota), a portable, closed-loop, oximetry-driven, O2-conserving device to maintain SpO2 at ≥ 90%, compared to continuous-flow oxygen and a standard O2-conserving device (CR-50, Puritan-Bennett, Pleasanton, California).
METHODS: We randomly assigned 28 patients who were on continuous home O2 for COPD to use each of 3 O2 delivery systems (continuous-flow O2, CR-50, and AccuO2) for 8 hours a day, for 2 consecutive days, at home, at their current O2 prescription. We recorded SpO2 and calculated the conservation ratio (duration of a given O2 supply with an O2-conserving device compared to continuous-flow O2).
RESULTS: Twenty-two patients completed all 3 study arms; 2 additional patients completed the AccuO2 arm and the continuous-flow O2 arm. The mean ± SD SpO2 was 92 ± 4% with continuous-flow O2, 92 ± 4% with the CR-50, and 91 ± 2% with AccuO2 (P = .006 for the AccuO2 vs continuous-flow O2, P = .03 for the AccuO2 vs the CR-50). SpO2 variability was less with the AccuO2 (P < .001 vs continuous-flow O2 and vs the CR-50). The conservation ratios were 9.9 ± 7.3 for the AccuO2 and 2.6 ± 1.0 for the CR-50 (P < .001).
CONCLUSIONS: Compared to continuous-flow O2 or the CR-50, the AccuO2 maintained SpO2 closer to the target, and AccuO2 had a higher conservation ratio than CR-50.

Entities:  

Mesh:

Year:  2011        PMID: 22288082

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  10 in total

Review 1.  Relationship between hyperoxemia and ventilator associated pneumonia.

Authors:  Karim Jaffal; Sophie Six; Farid Zerimech; Saad Nseir
Journal:  Ann Transl Med       Date:  2017-11

Review 2.  Optimal oxygen titration in patients with chronic obstructive pulmonary disease: a role for automated oxygen delivery?

Authors:  François Lellouche; Jed Lipes; Erwan L'Her
Journal:  Can Respir J       Date:  2013 Jul-Aug       Impact factor: 2.409

3.  Automated oxygen titration and weaning with FreeO2 in patients with acute exacerbation of COPD: a pilot randomized trial.

Authors:  François Lellouche; Pierre-Alexandre Bouchard; Maude Roberge; Serge Simard; Erwan L'Her; François Maltais; Yves Lacasse
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2016-08-24

4.  Cost-effectiveness of FreeO2 in patients with chronic obstructive pulmonary disease hospitalised for acute exacerbations: analysis of a pilot study in Quebec.

Authors:  Thomas G Poder; Christian R C Kouakou; Pierre-Alexandre Bouchard; Véronique Tremblay; Sébastien Blais; François Maltais; François Lellouche
Journal:  BMJ Open       Date:  2018-01-23       Impact factor: 2.692

5.  Automated oxygen administration versus conventional oxygen therapy after major abdominal or thoracic surgery: study protocol for an international multicentre randomised controlled study.

Authors:  Erwan L'her; Samir Jaber; Daniel Verzilli; Christophe Jacob; Brigitte Huiban; Emmanuel Futier; Thomas Kerforne; Victoire Pateau; Pierre-Alexandre Bouchard; Maellen Gouillou; Emmanuel Nowak; François Lellouche
Journal:  BMJ Open       Date:  2019-01-17       Impact factor: 2.692

6.  Automated oxygen control with O2matic® during admission with exacerbation of COPD.

Authors:  Ejvind Frausing Hansen; Jens Dahlgaard Hove; Charlotte Sandau Bech; Jens-Ulrik Stæhr Jensen; Thomas Kallemose; Jørgen Vestbo
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2018-12-14

7.  Automated Oxygen Delivery in Hospitalized Patients with Acute Respiratory Failure: A Pilot Study.

Authors:  Foteini Malli; Stelios Boutlas; Nick Lioufas; Konstantinos I Gourgoulianis
Journal:  Can Respir J       Date:  2019-02-03       Impact factor: 2.409

8.  Feasibility and reliability of an automated controller of inspired oxygen concentration during mechanical ventilation.

Authors:  Kaouther Saihi; Jean-Christophe M Richard; Xavier Gonin; Thomas Krüger; Michel Dojat; Laurent Brochard
Journal:  Crit Care       Date:  2014-02-19       Impact factor: 9.097

9.  Evaluation of a Novel Ear Pulse Oximeter: Towards Automated Oxygen Titration in Eyeglass Frames.

Authors:  Fabian Braun; Christophe Verjus; Josep Solà; Marcus Marienfeld; Manuela Funke-Chambour; Jens Krauss; Thomas Geiser; Sabina A Guler
Journal:  Sensors (Basel)       Date:  2020-06-10       Impact factor: 3.576

10.  Efficacy and safety of oxygen-sparing nasal reservoir cannula for treatment of pediatric hypoxemic pneumonia in Uganda: a pilot randomized clinical trial.

Authors:  Jerry Mulondo; Stella Maleni; Hellen Aanyu-Tukamuhebwa; Ezekiel Mupere; Alfred Onubia Andama; Chin Hei Ng; Stephen Burkot; Ella M E Forgie; Qaasim Mian; Christine M Bachman; Gerard Rummery; Daniel Lieberman; David Bell; Michael T Hawkes; Akos Somoskovi
Journal:  BMC Pulm Med       Date:  2020-08-31       Impact factor: 3.317

  10 in total