Literature DB >> 22285605

Diagnostic accuracy of parotid CT for identifying Sjögren's syndrome.

Zhipeng Sun1, Zuyan Zhang, Kaiyuan Fu, Yanping Zhao, Denggao Liu, Xuchen Ma.   

Abstract

PURPOSE: To evaluate the diagnostic accuracy of computed tomography (CT) of the parotid gland for Sjögren's syndrome in comparison with conventional X-ray sialography.
METHODS: CT scans and X-ray sialography were performed in 34 patients with confirmed Sjögren's syndrome and 22 symptomatic controls without the disease. CT data from 57 asymptomatic controls were included for quantitative analysis. The CT findings of heterogeneity, abnormal diffuse fat tissue deposition, diffuse punctate calcification, swelling or atrophy, nodularity or cystic changes of the parotid gland were analyzed by two independent blinded readers. The correlation between CT and X-ray sialography findings was evaluated. Diagnostic performance and receiver operating characteristics curves were calculated.
RESULTS: On CT, heterogeneity of the parotid gland was seen in 30/31 (reader 1/reader 2) Sjögren's syndrome patients by the two readers (sensitivity 88.2%/91.2%; specificity 100%/90.9%). Abnormal diffuse fat tissue deposition was seen in 28/28 SS patients by the readers (sensitivity 82.3%/82.3%; specificity 100%/90.9%). Diffuse punctate calcification was seen in 10/12 Sjögren's syndrome patients (sensitivity 29.4%/35.2%; specificity 100%/100%). Stagings of CT findings correlate positively with sialography. The areas under the receiver operating characteristics curves were 0.887 (P=0.000) and 0.908 (P=0.000) for the maximum and standard deviation (SD) of the CT value.
CONCLUSIONS: Parotid CT is accurate and reliable in the diagnosis of Sjögren's syndrome. Heterogeneity, abnormal diffuse fat tissue deposition, and diffuse punctate calcification are specific for Sjögren's syndrome. CT attenuation analysis is helpful in diagnosis.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22285605     DOI: 10.1016/j.ejrad.2011.12.034

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  14 in total

Review 1.  Sjögren Syndrome and Other Causes of Sicca in Older Adults.

Authors:  Alan N Baer; Brian Walitt
Journal:  Clin Geriatr Med       Date:  2017-02       Impact factor: 3.076

Review 2.  Update on Sjögren Syndrome and Other Causes of Sicca in Older Adults.

Authors:  Alan N Baer; Brian Walitt
Journal:  Rheum Dis Clin North Am       Date:  2018-08       Impact factor: 2.670

3.  Unusual Sjögren's Syndrome with Bilateral Parotid Cysts.

Authors:  Bommie Florence Seo; Rock Kuen Ju; Seung-Ki Kwok; Deuk Young Oh
Journal:  Arch Craniofac Surg       Date:  2014-08-14

Review 4.  Machine Learning in Rheumatic Diseases.

Authors:  Mengdi Jiang; Yueting Li; Chendan Jiang; Lidan Zhao; Xuan Zhang; Peter E Lipsky
Journal:  Clin Rev Allergy Immunol       Date:  2021-02       Impact factor: 8.667

5.  The value of 68 Ga-PSMA-11 positron emission tomography/computerized tomography in evaluating the lacrimal and salivary glands function.

Authors:  Jian-Fang Li; Lu-Ping Qin; Qing-Yu Wu; Xing-Hua Guo; Jie-Zheng Yang; Qi-Chang Wan; Mu-Hua Cheng; Liang-Jun Xie
Journal:  Clin Rheumatol       Date:  2022-01-28       Impact factor: 2.980

6.  Multiple microlithiasis in bilateral parotid glands as the initial clinical manifestation of primary Sjögren's syndrome.

Authors:  Adrienn Dobai; Levente Pataky; József Barabás
Journal:  Oral Radiol       Date:  2017-06-12       Impact factor: 1.852

7.  Preliminary study on the application of deep learning system to diagnosis of Sjögren's syndrome on CT images.

Authors:  Yoshitaka Kise; Haruka Ikeda; Takeshi Fujii; Motoki Fukuda; Yoshiko Ariji; Hiroshi Fujita; Akitoshi Katsumata; Eiichiro Ariji
Journal:  Dentomaxillofac Radiol       Date:  2019-05-22       Impact factor: 2.419

8.  Usefulness of a deep learning system for diagnosing Sjögren's syndrome using ultrasonography images.

Authors:  Yoshitaka Kise; Mayumi Shimizu; Haruka Ikeda; Takeshi Fujii; Chiaki Kuwada; Masako Nishiyama; Takuma Funakoshi; Yoshiko Ariji; Hiroshi Fujita; Akitoshi Katsumata; Kazunori Yoshiura; Eiichiro Ariji
Journal:  Dentomaxillofac Radiol       Date:  2019-12-11       Impact factor: 2.419

9.  Effectiveness of imaging modalities for screening IgG4-related dacryoadenitis and sialadenitis (Mikulicz's disease) and for differentiating it from Sjögren's syndrome (SS), with an emphasis on sonography.

Authors:  Mayumi Shimizu; Kazutoshi Okamura; Yoshitaka Kise; Yohei Takeshita; Hiroko Furuhashi; Warangkana Weerawanich; Masafumi Moriyama; Yukiko Ohyama; Sachiko Furukawa; Seiji Nakamura; Kazunori Yoshiura
Journal:  Arthritis Res Ther       Date:  2015-08-23       Impact factor: 5.156

10.  Radiological imaging features of the salivary glands in xerostomia induced by an immune checkpoint inhibitor.

Authors:  Kouji Katsura; Saori Funayama; Kayoko Ito; Kaname Nohno; Noboru Kaneko; Masaki Takamura; Marie Soga; Taichi Kobayashi; Takafumi Hayashi
Journal:  Oral Radiol       Date:  2020-09-07       Impact factor: 1.852

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.