Literature DB >> 22285328

Mitral valve annuloplasty and papillary muscle relocation oriented by 3-dimensional transesophageal echocardiography for severe functional mitral regurgitation.

Khalil Fattouch1, Giacomo Murana, Sebastiano Castrovinci, Claudia Mossuto, Roberta Sampognaro, Maria Giuliana Borruso, Emanuela Clara Bertolino, Giuseppa Caccamo, Giovanni Ruvolo, Patrizio Lancellotti.   

Abstract

OBJECTIVE: The study of the mitral valve apparatus and its modifications during functional mitral regurgitation (FMR) is better revealed by 3-dimensional (3D) transesophageal echocardiography (TOE). To plan mitral valve repair by annuloplasty and papillary muscle (PPM) relocation, we proposed a valve repair procedure oriented by the new main features obtained by real-time 3D TOE reconstruction of the mitral valve apparatus.
METHODS: Since January 2008, 25 patients with severe FMR before mitral valve repair were examined. Mean coaptation depth and mean tenting area were 1.3 ± 0.2 cm and 3.2 ± 0.5 cm(2), respectively. Intraoperative 2D and 3D TOE were performed, followed by a 3D offline reconstruction of the mitral valve apparatus. A schematic mitral valve apparatus model was obtained. A geometric model like a truncated cone was traced in according to the preoperative measurements. The size of the prosthetic ring was selected preoperatively according to the anterior leaflet surface. The expected truncated cone after annuloplasty was retraced. A conventional normal coaptation depth about 0.6 cm was used to detect the new position of the PPM tips.
RESULTS: Offline reconstruction of the mitral valve apparatus and respective truncated cone were feasible in all patients. The expected position of the PPM tips desirable to reach a normal tenting area with a coaptation depth 0.6 cm or less was obtained in all patients. After surgery, all parameters were calculated and no statistically significant difference was found compared with the expected data.
CONCLUSIONS: PPM relocation plus ring annuloplasty reduce mitral valve tenting and may improve mitral valve repair results for patients with severe FMR. This technique may be easily and precisely guided by preoperative offline 3D echocardiographic mitral valve reconstruction. Copyright Â
© 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22285328     DOI: 10.1016/j.jtcvs.2012.01.010

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  9 in total

Review 1.  Therapeutic decision-making for patients with fluctuating mitral regurgitation.

Authors:  Patrizio Lancellotti; Khalil Fattouch; Giovanni La Canna
Journal:  Nat Rev Cardiol       Date:  2015-02-10       Impact factor: 32.419

Review 2.  [Application fields of intraoperative transesophageal 3D echocardiography].

Authors:  H Magunia; P Rosenberger
Journal:  Anaesthesist       Date:  2014-09       Impact factor: 1.041

Review 3.  Surgical management of moderate ischemic mitral valve regurgitation: Where do we stand?

Authors:  Khalil Fattouch; Sebastiano Castrovinci; Giacomo Murana; Marco Moscarelli; Giuseppe Speziale
Journal:  World J Cardiol       Date:  2014-11-26

4.  Eliminating Regurgitation Reduces Fibrotic Remodeling of Functional Mitral Regurgitation Conditioned Valves.

Authors:  Patrick S Connell; Dragoslava P Vekilov; Christine M Diaz; Seulgi E Kim; K Jane Grande-Allen
Journal:  Ann Biomed Eng       Date:  2018-02-05       Impact factor: 3.934

5.  Assessment of mitral valve complex by three-dimensional echocardiography: therapeutic strategy for functional mitral regurgitation.

Authors:  Kiyoshi Yoshida; Kikuko Obase
Journal:  J Cardiovasc Ultrasound       Date:  2012-06-25

Review 6.  Role of modern 3D echocardiography in valvular heart disease.

Authors:  Takahiro Shiota
Journal:  Korean J Intern Med       Date:  2014-10-31       Impact factor: 2.884

7.  Commentary: Papillary muscle relocation for secondary mitral regurgitation: A never-ending story.

Authors:  Giacomo Murana; Davide Pacini
Journal:  JTCVS Open       Date:  2021-05-26

8.  Real-time three-dimensional transesophageal echocardiography to predict artificial chordae length for mitral valve repair.

Authors:  Huan-lei Huang; Xu-jing Xie; Hong-wen Fei; Xue-jun Xiao; Jing Liu; Jian Zhuang; Cong Lu
Journal:  J Cardiothorac Surg       Date:  2013-05-30       Impact factor: 1.637

Review 9.  The evolving role of cardiac magnetic resonance in primary mitral regurgitation: ready for prime time?

Authors:  Boyang Liu; Nicola C Edwards; Dudley Pennell; Richard P Steeds
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2019-02-01       Impact factor: 6.875

  9 in total