Literature DB >> 22285234

Factors affecting the postoperative limb alignment and clinical outcome after Oxford unicompartmental knee arthroplasty.

Seung-Ju Kim1, Ji-Hoon Bae, Hong Chul Lim.   

Abstract

We evaluated the postoperative mechanical axis deviation and clinical outcome according to bearing size, femoral component position, and tibial resection angle after unicompartmental knee arthroplasty (UKA). A total of 104 patients with 124 knees underwent Oxford phase 3 UKA. The overall changes in mechanical axis deviation and tibiofemoral angle were significantly different according to bearing size (P = .001 and < .001), but they were not significantly different according to the tibial resection angle and femoral component position. The postoperative mechanical axis fell into the zone C or zone 2 in 108 knees (87%) and into the zone 3 or zone 4 in 16 cases (13%). One hundred eight cases, which had the mechanical axis passing the zone C or zone 2, did not show any progression of arthritis. Limb alignment is a function of the thickness of the bearing rather than alignments of femoral and tibial implant.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22285234     DOI: 10.1016/j.arth.2011.12.011

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  14 in total

Review 1.  Fixed- versus mobile-bearing UKA: a systematic review and meta-analysis.

Authors:  Geert Peersman; Bart Stuyts; Tom Vandenlangenbergh; Philippe Cartier; Peter Fennema
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-24       Impact factor: 4.342

2.  Is tibial cut navigation alone sufficient in medial unicompartmental knee arthroplasty? Continuous series of fifty nine procedures.

Authors:  Thomas Gicquel; Jean Christophe Lambotte; Jean Louis Polard; Mickael Ropars; Denis Huten
Journal:  Int Orthop       Date:  2016-06-30       Impact factor: 3.075

3.  Medial joint line elevation of the tibia measured during surgery has a significant correlation with the limb alignment changes following medial unicompartmental knee arthroplasty.

Authors:  Yuichi Kuroda; Koji Takayama; Kazunari Ishida; Shinya Hayashi; Shingo Hashimoto; Masanori Tsubosaka; Takehiko Matsushita; Takahiro Niikura; Kotaro Nishida; Ryosuke Kuroda; Tomoyuki Matsumoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-16       Impact factor: 4.342

4.  Risk factors of post-operative malalignment in fixed-bearing medial unicompartmental knee arthroplasty.

Authors:  Ji Hyun Ahn; Ho Won Kang; Tae Yeong Yang; Jang Yun Lee
Journal:  Int Orthop       Date:  2015-10-10       Impact factor: 3.075

5.  Patient-specific instruments: industry's innovation with a surgeon's interest.

Authors:  Emmanuel Thienpont; Johan Bellemans; Hendrik Delport; Philippe Van Overschelde; Bart Stuyts; Karl Brabants; Jan Victor
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-14       Impact factor: 4.342

6.  The effect of C-arm fluoroscope on unicompartmental knee replacement arthroplasty.

Authors:  Hee-Gon Park; Kun-Woong Yu; Sung-Hyun Kim; Dong-Ho Lee
Journal:  J Orthop       Date:  2018-08-10

7.  Impact of patellar height on unicompartment knee arthroplasty: does patella baja lead to an inferior outcome?

Authors:  Devdatta Suhas Neogi; Ji Hoon Bae; Chang Woo Seok; Hong Chul Lim
Journal:  J Orthop Traumatol       Date:  2014-03

8.  Mobile-bearing medial unicompartmental knee arthroplasty restores limb alignment comparable to that of the unaffected contralateral limb.

Authors:  Arun B Mullaji; Siddharth Shah; Gautam M Shetty
Journal:  Acta Orthop       Date:  2016-10-31       Impact factor: 3.717

9.  Correction of coronal alignment correlates with reconstruction of joint height in unicompartmental knee arthroplasty.

Authors:  U Kuwashima; K Okazaki; Y Tashiro; H Mizu-Uchi; S Hamai; S Okamoto; K Murakami; Y Iwamoto
Journal:  Bone Joint Res       Date:  2015-08       Impact factor: 5.853

10.  Intentionally Increased Flexion Angle of the Femoral Component in Mobile Bearing Unicompartmental Knee Arthroplasty.

Authors:  Kye-Youl Cho; Kang-Il Kim; Sang-Jun Song; Kyu-Jin Kim
Journal:  Knee Surg Relat Res       Date:  2018-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.